B
Status • Reports
APEX1000 All-Purpose Edge QAM Software Version 2.4.x • Installation and Operation Manual
252
573408-001-a
GigE Output Packet Statistics screen field definitions
Item
Definition
TS:QAM
The Output Transport Stream number and Output QAM channel.
Stream Status
Summary of the possible alarms associated with an output stream, such as:
•
Output Stream Overflow
•
Output Stream Threshold
•
Output Stream Host IP Overflow
•
QAM Fault
•
Upconverter Fault
The highest current fault is indicated by each LED. The alarm indications are as
follows:
•
Green
– no alarm
•
Gray
– cause of alarm is indeterminate
•
Yellow
– warning
•
Blue
– minor
•
Magenta
– major
•
Red
– critical
If an LED alarm indication is active, display the
window to determine
which of the above Output Transport Stream alarms is causing the event.
*Packets Per Second
Number of GigE MPEG packets routed from GigE input to an output stream in
the last second.
*Data Rate (Mbps)
Data rate of GigE MPEG packets routed from GigE input to an output stream.
*Total GigE MPEG
Packets
Total number of GigE MPEG packets routed from GigE input to an output
stream.
Refresh
Click to update the information on the screen.
*
Average is taken over the preceding five seconds.