B
SimulCrypt • ECMG Statistics
APEX1000 All-Purpose Edge QAM Software Version 2.4.x • Installation and Operation Manual
206
573408-001-a
Item
Definition/Range
Min CP Duration
Displays (in hundreds of milliseconds) the SimulCrypt Timing parameter reported
by the ECMG entity.
This value represents the minimum supported amount of time a control word will
be active before it can be changed.
Last Error
Displays the error code for the last error situation detected by the APEX for the
corresponding ECMG channel.
AC Delay Stop
Displays the SimulCrypt Timing parameter reported by the ECMG entity.
This value represents (in milliseconds) the amount of time between the end of a
Crypto Period and the end of the broadcasting of the ECM attached to this period
for the last Crypto Period preceding a change in Access Criteria.
Channel Delay Stop
Displays the SimulCrypt Timing parameter reported by the ECMG entity.
This value represents (in milliseconds) the amount of time between the end of a
Crypto Period and the end of the broadcasting of the ECM attached to this period.
Trans Delay Stop
Displays the SimulCrypt Timing parameter reported by the ECMG entity.
This value represents (in milliseconds) the amount of time between the end of a
Crypto Period, and the end of the broadcasting of the ECM attached to this period
for the last crypto period preceding a scrambled to clear transition.
ECM Format
Shows the format expected for ECM received from ECMG entity.
Values are:
•
Section
•
Packet
Max Streams
Displays the number of ECM streams supported by the corresponding ECMG
entity as reported at channel connection.
CW Per Message
Displays the number of control words needed by the ECMG per control word
provision message as reported by the corresponding ECMG entity.
Channel Fault
ECMG channel status.
Values are:
•
ok
•
indeterminate
•
warning
•
minor
•
major
•
critical
Details
window.