RPC Mode Specific Configuration
When the APEX1000 is configured for RPC SDV mode, only the input-output pairing
must be configured through the EM. (This process assumes the RPC session controller
is already configured
and
operating correctly.)
To configure session control mode specific settings, select
SDV >
RPC Session
Control
.
The RPC Session Control window displays:
To configure an RPC Session:
1.
Select a Primary and a Secondary GigE interface for each QAM.
Note: Primary and Secondary interfaces for a transport stream must be either GigE1
and GigE2
or
GigE3 and GigE4.)
2.
Click
Apply
to validate these settings in the APEX1000.