03. INSTALLATION

ASSEMBLE THE SHAFT

Leave an excess of 350mm on the spring shaft beyond the bracket. Insert a protective 

washer onto the shaft.

FITTING THE MOTOR

Place the motor on the shaft leaving about 3 to 10 cm on both sides of the motor (detail A).

MARK THE HOLES

Place the plate on the motor without tightening it completely.

Place the plate against the wall and mark the holes.

DRILL THE HOLES

Remove the motor plate and drill holes to secure the motor.

FIX THE MOTOR

Fasten the plate to the wall and then to the motor.

Place the protection ring on the shaft, touch the motor and tighten it.

AUTOMATION INSTALLATION

• The gearmotor must be installed in a protected area, without risk of damage.

• The fixing surface must be solid.

• Appropriate accessories must be used to fix the motor to the fixing surface.

• Install pipes suitable for the passage of electrical cables, in order to guarantee full protec-

tion against mechanical damage.

• The door frame must be strong enough, with efficient hinges.

• There must be no friction between fixed parts and moving parts.

DETAIL A

You can install the motor horizontally or vertically, the procedure is the same.

See detail A.

Summary of Contents for KVM205

Page 1: ...v1 1 REV 07 2022 KVM105EV KVM110EV KVM115EV KVM205 KVM210 KVM215 EN USER INSTALLER MANUAL...

Page 2: ...stems This marking on the product or literature indicates that the product and electronic accessories eg Charger USB cable electronic material controls etc should not be disposed of as other household...

Page 3: ...y persons with experienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the...

Page 4: ...tion unlocktheautomatism turn off the power and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve i...

Page 5: ...TION 02 THE AUTOMATION TECHNICAL CHARACTERISTICS MANUAL OPENING CLOSING PACKAGE 01 01 KVM Motor 02 01 Maneuvers board with control board 03 01 Motor fixing plate 04 01 Chain 05 02 Protection ring 06 0...

Page 6: ...thermal protection line 03 Motor lead wire 04 Numerical tube 05 Terminal 06 Waterproof connectors 07 Power line 08 Signal line 01 02 03 04 05 06 08 White GND Yellow B White A Vcc White Blue Brown Bla...

Page 7: ...motor FIX THE MOTOR Fasten the plate to the wall and then to the motor Place the protection ring on the shaft touch the motor and tighten it AUTOMATION INSTALLATION The gearmotor must be installed in...

Page 8: ...7 8 9 10 11 FUSE CN2 CN3 CN4 CN5 CN1 EN EN 03 INSTALLATION INSTALLATION GUIDE 1500mm Maneuver board with control board Motor MARK THE HOLES Make a mark on the wall at a distance of 1500mm from the fl...

Page 9: ...OPEN STOP CLOSE KEY 6 SET OPEN button used to open the door STOP button stops the door movement CLOSE button used to close the door SET button used to confirm and enter the menus BUTTONS 04 PROGRAMMIN...

Page 10: ...0 P2 04 Excessive closing alarm 10 200 50 P2 05 Photocells distance 1 30000 500 P2 06 Current coefficient 50 90 90 P2 07 Braking frequency 15 35 20 P2 08 Locked rotor time 10 70 at 70 this function is...

Page 11: ...down PARAMETER P3 PASSWORD 00000 Number Instructions Configurable values Factory value P3 01 Change password 0 99999 00000 P3 02 Working time settings days 0 99999 99999 P3 03 Number settings maneuver...

Page 12: ...8 9 10 11 COM NC COM Central Central CH1 0V CH2 12 24 Recetor MR5 CH1 0V 12 24 Recetor MR17 TX RX EN 06 CONNECTION SCHEME Display Board Buttons Board Motor Encoder Cable Control board Control board MR...

Page 13: ...photocells safety edges If START LEDs are on there is a remote control issuing device emitting a permanent signal A SECURITY SYSTEMS 1 Shut down all security systems on the control board refer to the...