04. PROGRAMMING
05. TROUBLESHOOTING
PARAMETER SETTING
PARAMETER P3 SETTINGS
1
• Press and hold the SET button for more than 3 seconds, the display will show P0. Click on the OPEN but-
ton and select parameter P3.
2
• Then press OPEN or CLOSE button (display data can change between P1, P2, P3).
3
• Change to parameters P3, and then press the SET key. In the displayed digital box, enter the password
00000. Now press SET button to change points (at this time, SET button for digital scroll keys, movable
digital cursor for single digits, decimals, hundreds, thousands units and then with OPEN button respectively,
CLOSE button adjusts all data in digits up and down).
4
• Press the SET key until it shows P3-01. With the OPEN or CLOSE button you can choose the need to adjust
the parameters above and below.
5
• Continue to press the SET button and enter the corresponding parameter settings. At this time, more than
100 digits of data adjustment need SET button shift button, data adjustment of more than ten digits just
needs to press and hold OPEN or CLOSE button (there is an automatic adjustment of data), release and then
stop; For small data adjustments, just press OPEN or CLOSE button once and adjust up and down.
6
• At each parameter adjustment, be careful to press the SET button to save. Press STOP button, step-by-step
after exit to main menu, can start working normally.
3
• Change to parameters P3, and then press the SET key. In the displayed digital box, enter the password
00000. Now press SET button to change points (at this time, SET button for digital scroll keys, movable,
digital cursor for single digits, decimals, hundreds, thousands units and then with OPEN button respectively,
CLOSE button adjusts all data in digits up and down).
PARAMETER P3 : PASSWORD 00000
Number
Instructions
Configurable values
Factory value
P3 - 01
Change password
0 - 99999
00000
P3 - 02
Working time settings (days)
0 - 99999
99999
P3 - 03
Number settings (maneuvers)
0 - 99999
99999
P3 - 04
View total elapsed time (days)
0 - 99999
Current time
P3 - 05
See the running number
0 - 99999
Current number
P3 - 06
See the running number (the number of more
than 10 000 samples)
0 - 99999
Current number
ERRORS MAP
CIRCUIT BOARD FAULT CODE - REASON AND SOLUTION
Error Code
Instructions
Reason
ERR01
Lack of energy
Three-phase 380V L2 phase missing
ERR02
Encoder not connected
Encoder cables
ERR03
Anomalia nos cursos
Limit not set or limit beyond set
value
ERR04
Electrical short-circuit
Motor cables in short-circuit or
excessive power supply
ERR05
Overcharged motor
Motor current is greater than the
set value
ERR06
End of programmed cycles
Reset execution times or number of
maneuver executions
ERR07
Blocked motor
Motor contact missing (press ENTER
to reset)
ERR09
Motor thermal protection
Waiting for the engine to cool down
ERR10
Abnormal small door
Check wires or replace switch
ERR11
Overheating of thr Frequency conversion board
Inverter overheat protection
MANUAL CHAIN USE METHOD
When it is necessary to operate the door motor manually,
the safety chain will be used.
It is advisable to operate the chains with uniform movemen-
ts and continuous force. sudden impulses of
chain should be avoided, in order to avoid damage to the
manual mechanism.
Pull the chain to open and close the door.
During pulling, protection switches located on the chain's
manual mechanism automatically turn off power to prevent
accidents. Once the chain returns, the manual chain mecha-
nism will be automatically restored to its original position
and the industrial door motor will be restored to will be
restored to the normal electrically driven state. When safety
chains are not in use, secure the chains to the wall.