04. PROGRAMMING
SET THE CODE SWITCH SETTINGS
CONNECTIONS
•
Dipper 1
must always be
set to
OFF
ON
•
allows access to the programming
menu;
OFF
•
DOES NOT allow access to the
programming menu.
CONNECTIONS OF ELECTRIC LIMIT SWITCH
CN1
L
• 230V power
N
• 230V power
PE
• Ground wire
U
• Motor output
V
• Motor output
W
• Motor output
-
-
-
Blue
Brown
Black
CN2
01
•
GND
Negative enconder
02
•
B
RS485B
03
•
A
RS485A
04
•
VCC
Positive Encoder
Green
Purple
Pink
Red
CN3
01
•
COM
Common
02
•
OH
Thermal protection input (NC)
03
•
OP
Open
04
•
CL
Close
05
•
ST
Stop
06
•
RAD
Door protection
07
•
COM
Common
White cable
Yellow cable
-
-
-
-
-
CN4
08
•
+24V
Extra power output
(max 200mA)
09
•
COM
Common
10
•
INF
Photocells
CN5
01
•
F1
Multifunction output (NO)
02
•
CO
Multifunction Output (COM)
OPEN
STOP
CLOSE
KEY-6
SET
OPEN
button: used to open the door;
STOP
button: stops the door movement;
CLOSE
button: used to close the door.
SET
button: used to confirm and enter the menus;
BUTTONS
04. PROGRAMMING
LED
DESCRIPTION
ON
OFF
D13
Power supply
Power Supply ON
Power Supply OFF
D15
OH
input
(hoist/motor overheating)
Everything OK
• Overheating motor
• Hoist protection
(ERROR 9 is displayed)
D16
OP
input
(OPEN button)
NC
State
NO
State
D17
CL
input
(CLOSE button)
NC
State
NO
State
D18
ST
input
(STOP button)
NC
State
NO
State
D23
INF
input
(security device)
NC
State
NO
State
D24
RAD
input
(Step-by-step button)
NC
State
NO
State
LEDs
Input Code:
Manual
Mode
Automatic Closing
Mode
DISPLAY
Number
Instructions
STOP
OPEN
CLOSE
INFRA
DOR
Step-by-Step
Average limit
Interconnection
You can change the motors operating mode, between manual
mode and automatic closing mode, by pressing the STOP button
for 6 seconds.
Motor position /
Menu
Operating Mode