TRAX STOPPING DISTANCES
With Firmware Version 4.13 Trax is not using “traction control” therefore stopping distances will reduce
with future firmware updates. The support team at Motion Impossible will keep customers up to date
with improvements over the next few months.
After completing the Trax configuration, please move the magnets to the minimum operational position
as shown below (estimated for payloads of 20Kg).
Always test the stopping distance prior to use.
Maximum M/s
Maximum RPM
Minimum
Stopping Distance
Magnet Distance
MAG-Stop Side
Magnet Distance
Non-Sensor Side
1
500
1m
1.25m
2.25m
2
1000
2m
2.25m
3.25m
3
1500
5m
5.5m
6.5m
TOWER RANGE LIMITS
When operating Tower in Trax mode it is possible to limit the range of movement. To access this
function, press the dial to change the function mode.
STEER LIMIT enables TOWER LIMITS (Top and Bottom)
It is possible to set range limits on the Tower, once the Tower Limit – Top or Bottom has been selected
the percentage will switch to show the range. 0% bottom, 100% top. When the relevant limit is selected
the display will turn green whilst it is adjustable.
STEER RATE enables TOWER SPEED
Once STEER RATE now adjusts TOWER SPEED control, the Master display will show Tower Position.
TOWER
LIMIT -
Top
TOWER
LIMIT -
Bottom
STEER
LIMIT
Shown Stopping Distances are a recommendation only and must be tested prior to use.
The exact distance is subject to variation due to total payload of the complete system,