Table 2: Model Nomenclature
FURNACES INSTALLED IN THE COMMONWEALTH OF
MASSACHUSETTS ONLY
For all side wall horizontally vented gas fueled equipment installed
in every dwelling, building, or structure used in whole or in part for
residential purposes, including those owned or operated by the
commonwealth and where the side wall exhaust vent termination is
less than seven 7 feet (2.1336 m) above a finished grade in the area
of the venting. This is including but not limited to decks and
porches and the flowing requirements must be satisfied:
1.
INSTALLATION OF CARBON MONOXIDE DETECTORS
.
The installing plumber or pipe fitter shall observe that a hard
wired carbon monoxide detector with a battery backup shall be
installed on the same floor level where the gas fired appliance is
being installed with the horizontal vent system. In addition, the
installing plumber or pipe fitter shall observe that a battery
operated or hard wired carbon monoxide detector with an alarm
is installed on each additional level of the dwelling, building, or
structure served by the side wall horizontal vented gas fueled
equipment. It shall be the responsibility of the property owner to
secure the services of qualified licensed professionals for the
installation of hard wired carbon monoxide detectors.
a.
In the event that the side wall horizontally vented gas fueled
equipment is installed in a crawl space or an attic, the hard
wired carbon monoxide detector with alarm and battery
backup may be installed on the next adjacent level.
b.
In the event that the requirements of this subdivision cannot
be met at the time of completion of the installation, the
owner shall have thirty (30) days to comply with the above
48 requirements; provided; that during the said thirty (30)
day period, a battery operated carbon monoxide detector
with an alarm be installed.
2.
APPROVED CARBON MONOXIDE DETECTORS
Each of the carbon monoxide detectors are required by in
accordance with the above provisions and shall comply with
NFPA 720, be ANSI/UL 2034 listed and are IAS certified.
3.
SIGNAGE
A metal or plastic identification plate shall be permanently
mounted to the exterior of the building at a minimum height of
eight (8) feet (2.438 m) above the grade directly in line with the
gas fired appliance or equipment horizontal exhaust vent
terminal. The sign shall be in print of no less than one-half (1/2)
inch (12.7 mm) in size and shall read
“GAS VENT BELOW.
KEEP CLEAR OF ALL OBSTRUCTIONS”.
4.
INSPECTION
The state or local gas inspector of the side wall horizontally
vented gas fueled equipment shall not approve the installation
unless, upon inspection, the inspector observes carbon monoxide
detectors and signage installed in accordance with the provisions
of 248 CMR 5.08(2)(a)1 through 4.
Figure 1: Furnace Dimensions
Coil cabinet or insulated cabinet is not shown in Figure 1. Add 4
inches to the height for a heating only (AH3) models for the
insulated cabinet and 25.5 inches to the A/C Ready (CA3 and
CA4) models for the coil cabinet.
Total Height
Heating Only 51.852” + 4” =
55.852”
A/C Ready 51.852” + 25.5” =
77.352”
G - Ga s
G
18
18 - 80% Efficie nt
D
D - Dow nflow
060
060, 070, 077, 090
Heating Capacity
A
A = 56"
H
H - He a ting Only
3
B
A
A - Re vision Le tte r
Type of Blow e r
B - Consta nt Torque Motor
Indoor Blower
Horse Pow e r
3 = 1/3 HP 5 SPD
4 = 3/4 HP 5 SPD
Furnace Configuration
A - A/C Re a dy
C = 77.5"