80
MB300 XL Pro
rev.0.2 ID03570
A22
Machine with Cleaner
When the machine is switched off the head is cleaned
using the automatic cycle of the cleaner. Use the load
cycle to load the glue. The cart does not work with this
alarm.
A23
Carry out PINS maintenance !!!
The head valves do not work correctly. Call the technical
support service.
A31
Book too thick detected
The thickness detected by the device is under 2mm or
over 50mm. (OPTIONAL)
A33
Remove book from vice
The vice asks for positioning, reset the alarm and press
the START button.
A34
Place book in vice
The START button was pressed without having inserted
the book
A35
Book presence photocell in vice
blocked
Clean the photocell and reflector and check obstacles.
A36
Blocked glue photocell
Clean the photocell and reflector and check obstacles.
A37
Jogger unit out of position
It appears when you want to make a book without
milling and the jogger unit is not set to 0.
A38
Cutter door not closed
Check the mobile protection of the cutter and if
necessary clean the guide beneath.
A39
Cutter unit out of position
Check the lever of the cutter is in the ON or OFF
position.
A40
Press up/down unit not in
position
Height adjustment of the press not in position Press
the START button.
A41
Remove book from press
A42
Pins sensor error
Call support, check the pins command cart is not
blocked or the sensor is working properly.
A43
Place cover
Position the cover or check the sensor is working.
A44
Glue photocell wrong reading
The photocell has two or more impulses, do not insert
two books or clean the vice.
A45
TUTORIAL NON COMPLETED Complete the TUTORIAL to continue.
A46
Lack of Air
The minimum pressure was not reached, check the
pneumatic power supply
A47
PLC battery flat
Call the technical support service.
A48
End of production
It appears when the number of copies set on the
counter is reached.
A49
Threshold not reached - Check
tank closure
The pressure set by the machine is not reached. It can
also happen that during the glue level control, check
there are no air leaks in the premelter.
A50
Closed premelter air valve
During glue level control, the machine identified the
premelter valve is closed or there is some blockage
that prevents pressure entering the tank.
A51
Low Glue Level
The machine cannot guarantee book production.