62
MB300 XL Pro
rev.0.2 ID03570
8.2 CLEANING PROCEDURE FOR SPINE GLUE EXTRUDER
01
From the main page, select the advanced Set-up page.
02
Select the coating head advanced set-up page
03
Press reset
to open the head to the reset
position.
04
Insert the calibrated blade within the extrusion slit until the
bottom is reached and move it along the slot to remove or
unlock any possible occlusion.
05
Press and hold the spill glue button, indicated by the arrow,
for a few seconds until the glue can be seen leaking.
Check whether the extrusion of the glue is smooth and
continuous.
Otherwise, insert the calibrated blade and repeat the
cleaning process.
The tank pressure will switch off after 10 sec. of non-use.