18
Rev. 1.0
8/26/2015
TSM11 Hardware Manual
3.3.4 Programmable Output
The TSM11 has two digital outputs:
Y1/FAULT can be used as fault output or general purpose output.
Y2/BRAKE can be use as brake, in position, tach out or general
purpose output.
Diagrams of various connection types as follows:
Note: Do not connect the output to more than 30 volts. The current through the output
terminal must not exceed 100mA.
5-24 VDC
Power Supply
5-24 VDC
Power Supply
5-24 VDC
Power Supply
+
-
Driving a Relay
1N4935 suppression diode
relay
TSM11
Y1/Y2
V-
TSM11
Connecting a sinking output with PLC’s input
Note:Y1 and Y2 can not be used as sourcing output.
PLC
Y1/Y2
V-
COM
-
+
Load
TSM11
+
-
Connecting a Sinking Output
Y1/Y2
V-
IN
DSP
GND
Y1/Out1
Y2/Out2
Inside drive