17
Rev. 1.0
8/26/2015
TSM11 Hardware Manual
3.3.3 X3/EN & X4/AR Digital Inputs
The diagram below shows how to connect the X3/En & X4/AR Inputs to commonly used device.
Note: X3/En & X4/AR inputs have been internally pulled up to logical 3.3 VDC
Note: If the input voltage is between 5-24 VDC, or the input is not connected, the logic
state of that input is HIGH. If the input voltage is below 1VDC, the logic state of that input
is LOW.
DSP
GND
GND
10K
+
3.3V
10pF
50K
X3/EN
Inside drive
X4/AR
TSM11
EN
Connecting to Controller with Sinking Outputs
Note: Souring Outputs are not compatible to inputs X3/EN and X4/AR
Connecting to NPN type Proximity Sensor
Note: PNP type Proximity Sensor is not compatible to inputs X3/EN and X4/AR
AR
GND
X3/EN
X4/AR
V-
TSM11
OUT
OUT
GND
X3/EN
X4/AR
V-
5-24VDC
NPN
Sensor
5-24VDC
NPN
Sensor
TSM11
X4/AR
X3/EN
+
-
15 to 30V
Power
Supply
Using Mechanical Switches
V+