13
Rev. 1.0
0006302011
SSM23C User Manual
+86-400-820-9661
3 Installation/Connections
3.1 Connecting the Power Supply
Use 16 to 20-gauge wire to connect the SSM23 to a power supply. It contains an internal fuse
connected to the “+” terminal that is not user replaceable. If a user serviceable fuse is desired,
install a 4 amp fast acting fuse in line with the “+” power supply lead.
Be careful not to reverse the wires. Reversing the connection may open the
internal fuse on the drive and void the warranty.
RC880
SSM
V
-
V+
V
-
V+
Vin
-
+
Vout
+
-
To Power Supply-
To Power
To Earth Ground
Power Supply
23C-3CG
MOONS' offers two matched power supplies for use with the SSM.
A 24VDC, 150W(P/N MF150A24AG-V) and a 48VDC 320W(P/N MF320A48AG-V).
These power supplies have current over load capability making them ideal for use.
(To use with a switch power supplier, a RC880 regen must be connected in system)
The RC880 regeneration clamp is for use where regeneration from the motor may cause damage to
the drive. In these cases the RC880 is connected between the drive and power supply and absorbs