4.3.1 I/O Definition
Options for
IN1
are:
• At end of travel, CW limit input will be closed
• At end of travel, CW limit input will be open
• Not used - generic programmable input
Options for
IN2
are:
• At end of travel, CCW limit input will be closed
• At end of travel, CCW limit input will be open
• Not used - generic programmable input
Options for
IN3
are:
• Not used - generic programmable input
• Enable motor when closed - the motor has no power when the input is open
• Enable motor when open - the motor has no power when the input is closed
• Reset alarm when closing - an alarm or fault can be cleared by closing the input
• Reset alarm when opening - an alarm or fault can be cleared by opening the input
Options for
Output(OUT)
are:
• Not used - generic programmable output
• Closed on fault - the output will close if a fault occurs
• Open on fault - the output will open if a fault occurs
• Closed to release brake - the output controls a fail safe brake relay
• Open to release brake - the output opens to release the brake
• Tach out - the output produces pulses relative to the motor position
• Closed when position error less than - enter a count value in the box
• Open when position error less than - enter a count value in the box