P
ar
t
2: C
omman
d
s
Moog Animatics SmartMotor™ Developer's Guide, Rev. L
Page 741 of 909
EXAMPLE:
(Demonstrates relationship between TEMP, TH, and Bh)
GOSUB10
'Report TEMP, TH, and Bh
a=5
b=
TEMP
WHILE
a>-5
'Vary TH about the current TEMP
TH
=b-a
WAIT
=2000
GOSUB10
'Observe Bh flag change from 0 to 1
a
=a-1
'as TH is reduced to TEMP value and less
LOOP
END
C10
(#13,"Read the temperature ",b)
(#13,"Read TH overheat value ",
TH
)
(#13,"Read Bh overheat flag ",
Bh
)
RETURN
Program output is:
Read the temperature 0
Read TH overheat value 85
Read Bh overheat flag 0
Read the temperature 29
Read TH overheat value 24
Read Bh overheat flag 1
Read the temperature 29
Read TH overheat value 25
Read Bh overheat flag 1
Read the temperature 29
Read TH overheat value 26
Read Bh overheat flag 1
Read the temperature 29
Read TH overheat value 27
Read Bh overheat flag 1
Read the temperature 29
Read TH overheat value 28
Read Bh overheat flag 1
Read the temperature 29
Read TH overheat value 29
Read Bh overheat flag 1
Read the temperature 29
Read TH overheat value 30
Read Bh overheat flag 1
Read the temperature 29
Read TH overheat value 31
Read Bh overheat flag 1
Read the temperature 29
Read TH overheat value 32
Read Bh overheat flag 1
Read the temperature 29
Read TH overheat value 33
Read Bh overheat flag 1
RELATED COMMANDS:
R