P
ar
t
2: C
omman
d
s
Moog Animatics SmartMotor™ Developer's Guide, Rev. L
Page 365 of 909
EXAMPLE:
'Variables for DMX control:
b=1
'Set DMX base address Valid Address: 1 thru 512.
n=3
'Set number of DMX channels to use.
'NOTE: max that may be summed is 3 or 24 bit position unsigned int.
s=0
'First motor array variable index to use starting with aw[s].
'Configure DMX data usage and motor variable storage:
IF
n>3
("n too large.",#13)
END ENDIF
'Limit "n" based on a max of 3 bytes.
IF
b>(513-n)
("b too large.",#13)
END ENDIF
'Limit "b" based on max data slot.
IF
s>(102-n)
("s too large.",#13)
END ENDIF
'Limit "s" to max array value.
q=b+n-1
'Last data channel used (will be trigger when data received).
COMCTL
(1,b)
'Set base DMX channel to value from CADDR.
COMCTL
(2,n)
'Accept 1 DMX channel of data.
COMCTL
(3,q)
'Status word 12 bit 2 will be set to 1 when
'channel "q" arrives.
COMCTL
(4,s)
'Set start of array index storage (good for
'bypassing cam mode dynamic array).
OCHN
(DMX,1,N,250000,2,8,D)
'Open DMX channel: COM 1, no parity,
'250 kBd, 2 stop, 8 data, datamode.
RELATED COMMANDS:
Part 2: Commands: COMCTL(function,value)