Operation
XG0228 - 021419
Initializing the System for the first time
1. Set master override switch to off position.
2. Install four (4) AA batteries into the battery holder.
3. Install three (3) AAA batteries in the back of the remote
control. Note the polarity of batteries and install them as
LQGLFDWHGE\WKHVLONVFUHHQRQWKHKROGHU
4. Connect AC Power (115 volts, 60 Hz) to fireplace.
Operating the System for the first time
Press SW1 button on the control module. The control module will
beep three (3) times and an amber LED is illuminated to indicate
that the IFC (control board) is ready to synchronize with a remote
control within 10 sec. Push the ON button. The control module
will "beep" four (4) times to indicate transmitter's command is
accepted.
The System is now initialized.
Temperature Indication Display
With the system in the "Off" position, press the Thermostat Key
and the Mode Key at the same time. Look at the LCD screen on
the Remote Control to verify that a C or F is visible to the right of
the Room Temperature display.
Turn On the Fireplace
With the system Off, turn the master override switch to on and
SUHVVWKH2Q2II.H\RQWKH5HPRWH&RQWURO7KH5HPRWH&RQWURO
display will show some other active Icons on the screen. At the
same time the Control Module will activate the fireplace. A single
"beep" from the Control Module will confirm reception of the
command.
Turn Off the
Fireplace
With the system On, press
WKH2Q2II.H\RQWKH
Remote Control. The Remote
Control LCD display will only
show the room temperature.
At the same time the Control
Module will turn off the
fireplace. A single "beep"
from the Receiver confirms
reception of the command.
Figure 27.e
5HPRWH&RQWUROGLVSOD\LQ)DKUHQKHLW &HOVLXV
Figure 27.f
5HPRWH&RQWURO'LVSOD\
Remote-Flame Control
When you turn on the fireplace it starts on high. The proflame 2
has six (6) flame levels. Each time you press the Down Arrow Key
once the flame height will reduce by one step.
You can continue this until the main burner flame turns off. You
can still operate the accent lights and fans in this mode.
If the main burner flame is off and you press the up arrow key
once, the flame will automatically go to high.
Figure 27.g
)ODPH2DQG)ODPH/HYHO
Figure 27.h
)ODPH/HYHODQG)ODPH/HYHO0D[LPXP