27
Installation
XG0228 - 021419
POD - Pilot on Demand
What is POD and CPI mode?
7KLV ȴUHSODFH LV HTXLSSHG ZLWK DQ Ȋ2Q 'HPDQGȋ LQWHUPLWWHQW SLORW
ignition system (IPI) which also includes a continuous pilot ignition
(CPI) mode with an integrated seven day timer.
In IPI mode, the pilot will light before the main burner, when the appliance
is turned on using a wall switch, remote or from a thermostat. Once the
DSSOLDQFHLVWXUQHGRWKHPDLQEXUQHUDQGSLORWȵDPHZLOOVKXWGRZQ
The continuous (CPI) mode exists to ease the startup phase in colder
FOLPDWHVE\NHHSLQJWKHȴUHER[DQGYHQWLQJZDUPZKHQWKHPDLQEXUQHU
LVQRWLQXVH7KHWLPHUDXWRPDWLFDOO\VZLWFKHVRWKHSLORWZKHQWKH
appliance has not been used for seven days.
When the CPI function is turned on, the pilot will remain on after
WKHȴUHSODFHLVWXUQHGR$WLPHUZLOOWKHQEHJLQWKHFRXQWGRZQIRU
DSSUR[LPDWHO\VHYHQGD\VEHIRUHVKXWWLQJRWKHSLORWLIWKHDSSOLDQFH
is not used. This countdown will reset anytime the burner is use.
If your appliance is equipped with a remote control device capable of
VHOHFWLQJΖ3Ζ&3ΖPRGHVUHIHUWRUHPRWHRSHUDWLQJLQVWUXFWLRQV
In order to start your pilot, turning the main burner on with the
VZLWFKUHPRWHRUWKHUPRVWDWDQGWKHQWXUQLQJLWRZLOOUHDFWLYDWHWKH
continuous pilot mode and reset the seven day timer.
A jumper is supplied with this unit that can be plugged into the wire
harness connected to the controller. This jumper cable gives the
5HPRWH&RQWUROWKHDELOLW\WRRSHUDWHWKH32'Ζ3ΖVZLWFKDQGVHWWKH
unit to operate in either condition. Please refer to jumper installation
instructions for more information.
ΖQVWDOOLQJWKH&3Ζ-XPSHU&DEOH
1).
Access the control box.
2).
Remove the bag containing the Jumper Cable from the wire
harness connected to the controller.
3).
Find the corresponding plug attached to the control wire harness
and connect the CPI jumper.
See operation section to turn remote into CPI mode.
Figure 19.a
2SHQWKHFRQWUROER[GUDZHU
Figure 19.b
Locate Jumper cable
Figure 19.c
Connect CPI
Remote Continuous Pilot (CPI)
Selection
5HTXLUHVLQVWDOODWLRQRIWKH&3Ζ-803(5
With the system in "off" position press the Mode Key, to index to
the CPI mode icon, Pressing the Up Arrow Key will activate the
Continuous Pilot Ignition mode (CPI). Pressing the Down Arrow
Key will return to IPI. A single "beep" will confirm the reception of
the command.