![Mono DELTA DEPOSITOR Operation Manual Download Page 37](http://html1.mh-extra.com/html/mono/delta-depositor/delta-depositor_operation-manual_1827436037.webp)
FG073
– DELTA CONT. RevA17 10-4-17
37
1.
Speed Deposit
–
Sets the maximum linear speed value (up to a maximum preset value) for the forward and
reverse direction of the Deposit Pump axis (Axis 0) for the following conditions:
a) During depositing of product mix to make products in the absence of an alternative
value entered in a SPEED command line in the product program.
b) During suck back (i.e. in reverse direction) on completion of each deposited
product row in the absence of an alternative value entered in a SPEED
command line in the product program.
2.
Speed tray
–
Sets the maximum linear speed value (up to a maximum preset value) for the forward
and reverse direction of the tray conveyor axis (Axis 1) for the following conditions: -
a) During product creation in either forward or reverse direction in the absence of an
alternative value entered in a SPEED command line in the product program.
b) Between the point of completion of one product and the start of the next.
c) On return of the tray to the operator on completion of the depositing sequence when
the DELTA is operated in MANUAL mode.
3.
Speed jog
–
sets the maximum linear speed value (up to a maximum preset value) for the up and
down direction of the jog axis (axis 2) for the following conditions: -
a) During product creation in either up or down direction in the absence of an alternative
value entered in either a SPEED or SUCKBACK command line in the product
program
b) During downward movement (jog down) to bring the head down to the depositing
height from the previously jogged up height.
c) During the movement between the ‘Edge height’ value (see fig10) and the depositing
height of the first product on the tray.
d) During the movement between the jogged up height of the last product on the tray
and the ‘Edge height’ value.