Specification and Adjustment Manual - ARDAC IBA5
Document Number 44X501R2 – March 15, 2004
4-13
Dual Density Calibration
Dual Density Calibration Card (Money Controls part number 49x307) is required to perform this
calibration procedure. If this card is not available, obtain one from Money Controls before starting this
procedure.
CAUTION
Calibrating the acceptor with anything other than the calibration card specified will cause poor or
no note acceptance.
Calibration Procedure
1. Follow the instructions in the Diagnostics section of this manual to:
- Install and set-up the equipment for bench mode operations.
- Set up the Hyper Terminal software for bench mode operations.
- Start bench mode as described in the Diagnostics section above.
2. Once bench mode is active, access the Message Window. The screen display includes an auto
calibration status line that reads:
Autocalibrate: DISABLED
3. With the Message Screen displayed, start the Auto Calibration sequence by typing ACAL. The
CAPS software responds with the message:
Insert ND1 calibration card.
Or press ACAL again to deactivate
4. Using only a Money Controls 49x307 Calibration Card, insert the card into the acceptor.
5. The card is drawn into the acceptor and returned after a second.
6. The message “Calibration Passed” and the new calibration values display on the monitor. The unit
is calibrated.
7. At the end of its calibration sequence, the acceptor automatically leaves Auto Calibrate Mode.
When the Message Screen displays again, the Auto Calibration status line will read:
Autocalibrate: DISABLED