3. GETTING 

STARTED 

3.1 Power 

The ba ery powered Nova-Pro has a removable Ba ery 
Pack that should be charged before use (See Ba ery 
Pack sec on 8).  The Ba ery Pack is keyed to ensure  
correct inser on into the Nova-Pro and Ba ery 
Charger.  

Make sure to remove the tape protec ng the 

ba ery terminals and charge the ba ery before use.  

 

The AC powered Nova-Pro has an external power 
adapter that must be plugged into an AC outlet 
(115  Vac  or  230  Vac)  using  the  appropriate      
connector. Interchangeable plugs allow for opera-

on in most countries (See sec on 10). 

With the power source (battery or AC) inserted into the Nova-Pro, 
turn the unit on by pressing and holding the POWER button 
until the display illuminates, then release the button.  To operate the 
unit, pull the trigger.  The unit will remember the last mode used. 

To turn the unit o

 press and hold the POWER bu on un l 

the display shows OFF and then release. The unit will automa cally 
power o

 a er 3 minutes. 

3.1.1 Con nuous Opera on 

The unit can be locked in con nuous opera on by pressing the 
POWER bu on 

while squeezing the trigger.  Keep holding 

the POWER bu on as you release the trigger and the Lock icon 

will show on the display.  To remove the lock simply pull 

the trigger. 

 

 

3.2  Input / Output Connec ons 

The Nova-Pro has input and output jacks on 
the  side  that  can  be  used  for  external      
triggering or synchroniza on (daisy-
chaining two or more strobes).  These jacks 
accept 1/8” [3.5 mm] phone plugs (input-
stereo, output-mono). The input jack 

 

 

 

provides a source of power (5Vdc @ 75mA) to power an external 
sensor and will accept a signal from 3 to 12 volts.  The output is TTL 
compa ble (3V) and provides a pulse synchronized to the internal 
generator (

fl

ash rate) or external input signal.  Connec on details 

are shown in Figures 3 and 4 below.

 

Out (

§

§

In (

¨

Figure 3  Input Connector Detail (Stereo plug) 

Figure 4  Output Connector Detail (Mono plug) 

 

Common (GND) 

Pulse Output 
from Nova-Pro 

 

Pulse Output 

from Nova-Pro 

 

Common (GND) 

Common (GND) 

+5V Out to 
Sensor 

Signal Input 

 

Signal Input 

+5V Out to Sensor 

Common (GND)

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for Nova-Pro Ultra Violet UV365

Page 1: ...Nova Pro Ultra Violet UV365 UV385 Stroboscope Lamp Tachometer Instruction Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...ed to a reclama on facility for recovery of the metal and plas c components as the proper method of waste management Contact distributor for product return procedures TABLE OF CONTENTS 1 INTRODUCTION...

Page 3: ...u 21 5 6 1 NONE 22 5 6 2 PHASE 22 5 6 3 TIME 22 5 7 DELAY Menu 22 5 7 1 NONE 23 5 7 2 PHASE 23 5 7 3 TIME 23 5 7 4 VRPM 23 6 STROBE BRIGHTNESS 24 6 1 Calcula ng Blur 24 6 2 Brightness in Degrees of Ro...

Page 4: ...Table 1 Nova Pro Features 1 2 Bezel and Lens Bezel is removable to add or remove the Laser Module UV Emi ed from here 3 Laser Module Internal laser used to synch the flash to an external marker on th...

Page 5: ...h Keypad Numeric Used to directly enter precise flash rates 8 TACH icon Ac ve when Tachometer Mode is selected 9 x2 2 and arrows Used to double or halve the flash rate 10 POWER bu on Turns the unit on...

Page 6: ...Con nuous Opera on The unit can be locked in con nuous opera on by pressing the POWER bu on while squeezing the trigger Keep holding the POWER bu on as you release the trigger and the Lock icon will s...

Page 7: ...when the digit is changed if incremen ng the units digit 99 will roll over to 100 If the user does not increment or decrement a digit within 5 seconds the edit mode will be cancelled 7 Use joys ck or...

Page 8: ...00 FMP EVERY OTHER ROTATION 2 One target 3 000 FMP ONCE EVERY ROTATION 0 Two targets 6 000 FMP TWICE PER ROTATION X2 Four targets 12 000 FMP FOUR TIMES PER ROTATION X2 X2 flash each me a signal is rec...

Page 9: ...THROUGH OPTICAL INSTRUMENTS 4 4 TACH Tachometer Mode The TACH Tachometer Mode requires the Laser Module to be installed OR an external input sensor be plugged in This mode uses the Laser or External...

Page 10: ...CPT to SET none 1 2 3 RPS FPM FPS Nova Pro 500 and UVxxx Only When using an ex ternal input DOWN but ton MENU but ton POWER but ton NAVIGATIONkeypad DOWN but ton onkeypad KEY 14 SEtUP MODE STROBE MODE...

Page 11: ...e This will change the mode and exit the menu Press the POWER bu on to escape without changing the mode 5 3 Brightness BRITE Menu Refer to Sec on 8 for details on Brightness and Flash Dura on before u...

Page 12: ...hout changing the polarity press the Power bu on 19 5 4 5 BKLIT Backlight Menu This menu op on turns the backlight of the display ON or OFF Press the MENU bu on to enter the Backlight menu Use the arr...

Page 13: ...value of 600 will be displayed as 600 600 0 600 00 600 000 depending on the se ng 17 Press the MENU bu on to enter the DECPT menu The current value is shown on the top line with DECPT on the lower lin...

Page 14: ...d Jog method The op ons are NONE PHASE and TIME Press the MENU bu on to select a Jog method This will enter the sub menu for PHASE or TIME 21 5 6 1 NONE To cancel the JOG mode press the MENU bu on whe...

Page 15: ...shing the user can view the e ect of changing the RPM To exit the DELAY Menu press the Power bu on Press the Power bu on to escape back out of the setup menu 6 STROBE BRIGHTNESS The strobe s brightnes...

Page 16: ...z 25 6 3 Brightness in Pulse Dura on Brightness can also be set to a fixed duration pulse in microseconds The flash rate remains constant irrespective of the flash rate thus as the flash rate increase...

Page 17: ...respect to the trigger point 27 STOP MOTION 30 60 90 P PHASE TRIGGER POINT 30 60 90 Figure 9 Triggered Phase The Phase Delay tracks the speed of the target the strobe is con nuously compu ng the dela...

Page 18: ...ppropriate shipping methods 29 The Nova Pro Ba ery Pack is specifically keyed to fit in the Nova Pro and Charger Base one way only Insert the Ba ery Pack into the Nova Pro un l the clips lock into pla...

Page 19: ...385 nm Flash Range FPM RPM 30 to 999 999 Display 6 digit numeric and 5 digit alphanumeric LCD with touch keypad High contrast blue background white characters with backlight Accuracy Resolu on 0 001...

Page 20: ...gs Charger Power Supply Replacement power supply for use with Charging Sta on 115 230 Vac with USA UK AUS Euro adapter plugs Standard Ba ery Pack Replacement Standard Li Ion Ba ery Pack Long Life Ba e...

Page 21: ...other product lines Speed Sensors Temperature Humidity Sensors Vibra on Meters Paperless Recorders Track It Data Loggers Printed in the U S A Copyright 2017 Monarch Instrument all rights reserved 1071...

Reviews: