background image

5.3.2 Time 

To set the 

fl

ash dura on in  me instead of degrees, press the 

MENU bu on again (skip the DEG menu). 

Use the arrows on the joys ck to adjust to the  me value.  
Time can be set from 0.001 mSec to 1.000 mSec. 

Press the MENU 

bu on followed by the Power bu on   

to save the  me se ng. 

5.4  Miscellaneous (MISC) Menu 

This menu item contains seldom used op ons.  The miscellaneous 
items are: DECPT (Decimal Point), UNITS, INPUT, OUTP (Output) and 
BKLIT (Backlight). 

Press  the  MENU 

button to enter the MISC menu.  

Use the 

c

 and 

d

 arrows on the joys ck  to  scroll  through  the       

miscellaneous op ons.   

Press the MENU bu on to select the desired op on.  

Press the POWER bu on to exit/escape. 

5.4.1 

DECPT (Decimal Point) Menu 

The Decimal Point menu adjusts the resolution of the Flash/Tach 
rate displayed.  Up to three places after the decimal point can 
be shown.  The number of decimal places is limited by the  
6-digits available and the unit will auto range to show the
maximum number of digits after the decimal point selected by
the user. The choices are NONE, 1, 2, 3.  A value of 600 will be
displayed as 600, 600.0, 600.00, 600.000 depending on the
se ng. 

17 

Press the MENU 

bu on to enter the DECPT menu.  

The current value is shown on the top line with DECPT on the 
lower line.  The On-Target 

indicator  will  be  on  for  the 

currently  selected value. 

Use the arrows on the joys ck to select the desired value. 

Press the MENU bu on followed by the Power bu on   
to save the decimal point se ng. 

To exit without se ng the decimal point press the Power 

 bu on. 

5.4.2 UNITS 

Menu 

This menu op on selects the Engineering Units used to display 
the 

fl

ash rate or speed.  The choices are:  

FPM - Flashes per Minute (Not available in TACH Mode) 
FPS  - Flashes per Second (same as Hz, not available in TACH Mode) 
RPM -  Revolu ons per Minute 
RPS - Revolu ons per Second (same as Hz) 

Press the MENU 

bu on to enter the UNITS menu. Unit 

is shown on the top line with the current engineering unit on 
the lower line.  The On-Target indicator will be on for the  
currently selected value. 

Use the arrows on the joys ck to select the desired value. 

Press the MENU bu on followed by the Power 
bu on to save the value. 

To exit without se ng the units press the Power bu on. 

18 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for Nova-Pro Ultra Violet UV365

Page 1: ...Nova Pro Ultra Violet UV365 UV385 Stroboscope Lamp Tachometer Instruction Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...ed to a reclama on facility for recovery of the metal and plas c components as the proper method of waste management Contact distributor for product return procedures TABLE OF CONTENTS 1 INTRODUCTION...

Page 3: ...u 21 5 6 1 NONE 22 5 6 2 PHASE 22 5 6 3 TIME 22 5 7 DELAY Menu 22 5 7 1 NONE 23 5 7 2 PHASE 23 5 7 3 TIME 23 5 7 4 VRPM 23 6 STROBE BRIGHTNESS 24 6 1 Calcula ng Blur 24 6 2 Brightness in Degrees of Ro...

Page 4: ...Table 1 Nova Pro Features 1 2 Bezel and Lens Bezel is removable to add or remove the Laser Module UV Emi ed from here 3 Laser Module Internal laser used to synch the flash to an external marker on th...

Page 5: ...h Keypad Numeric Used to directly enter precise flash rates 8 TACH icon Ac ve when Tachometer Mode is selected 9 x2 2 and arrows Used to double or halve the flash rate 10 POWER bu on Turns the unit on...

Page 6: ...Con nuous Opera on The unit can be locked in con nuous opera on by pressing the POWER bu on while squeezing the trigger Keep holding the POWER bu on as you release the trigger and the Lock icon will s...

Page 7: ...when the digit is changed if incremen ng the units digit 99 will roll over to 100 If the user does not increment or decrement a digit within 5 seconds the edit mode will be cancelled 7 Use joys ck or...

Page 8: ...00 FMP EVERY OTHER ROTATION 2 One target 3 000 FMP ONCE EVERY ROTATION 0 Two targets 6 000 FMP TWICE PER ROTATION X2 Four targets 12 000 FMP FOUR TIMES PER ROTATION X2 X2 flash each me a signal is rec...

Page 9: ...THROUGH OPTICAL INSTRUMENTS 4 4 TACH Tachometer Mode The TACH Tachometer Mode requires the Laser Module to be installed OR an external input sensor be plugged in This mode uses the Laser or External...

Page 10: ...CPT to SET none 1 2 3 RPS FPM FPS Nova Pro 500 and UVxxx Only When using an ex ternal input DOWN but ton MENU but ton POWER but ton NAVIGATIONkeypad DOWN but ton onkeypad KEY 14 SEtUP MODE STROBE MODE...

Page 11: ...e This will change the mode and exit the menu Press the POWER bu on to escape without changing the mode 5 3 Brightness BRITE Menu Refer to Sec on 8 for details on Brightness and Flash Dura on before u...

Page 12: ...hout changing the polarity press the Power bu on 19 5 4 5 BKLIT Backlight Menu This menu op on turns the backlight of the display ON or OFF Press the MENU bu on to enter the Backlight menu Use the arr...

Page 13: ...value of 600 will be displayed as 600 600 0 600 00 600 000 depending on the se ng 17 Press the MENU bu on to enter the DECPT menu The current value is shown on the top line with DECPT on the lower lin...

Page 14: ...d Jog method The op ons are NONE PHASE and TIME Press the MENU bu on to select a Jog method This will enter the sub menu for PHASE or TIME 21 5 6 1 NONE To cancel the JOG mode press the MENU bu on whe...

Page 15: ...shing the user can view the e ect of changing the RPM To exit the DELAY Menu press the Power bu on Press the Power bu on to escape back out of the setup menu 6 STROBE BRIGHTNESS The strobe s brightnes...

Page 16: ...z 25 6 3 Brightness in Pulse Dura on Brightness can also be set to a fixed duration pulse in microseconds The flash rate remains constant irrespective of the flash rate thus as the flash rate increase...

Page 17: ...respect to the trigger point 27 STOP MOTION 30 60 90 P PHASE TRIGGER POINT 30 60 90 Figure 9 Triggered Phase The Phase Delay tracks the speed of the target the strobe is con nuously compu ng the dela...

Page 18: ...ppropriate shipping methods 29 The Nova Pro Ba ery Pack is specifically keyed to fit in the Nova Pro and Charger Base one way only Insert the Ba ery Pack into the Nova Pro un l the clips lock into pla...

Page 19: ...385 nm Flash Range FPM RPM 30 to 999 999 Display 6 digit numeric and 5 digit alphanumeric LCD with touch keypad High contrast blue background white characters with backlight Accuracy Resolu on 0 001...

Page 20: ...gs Charger Power Supply Replacement power supply for use with Charging Sta on 115 230 Vac with USA UK AUS Euro adapter plugs Standard Ba ery Pack Replacement Standard Li Ion Ba ery Pack Long Life Ba e...

Page 21: ...other product lines Speed Sensors Temperature Humidity Sensors Vibra on Meters Paperless Recorders Track It Data Loggers Printed in the U S A Copyright 2017 Monarch Instrument all rights reserved 1071...

Reviews: