background image

(0 to 60 RPM).  This gives a “slow-motion” effect and enables the 
target to be examined as it moves through a complete cycle or 
revolution.  The display will show the 

AUTO 

icon to indicate the 

Delay Mode with the virtual speed in RPM on the top line and 
will indicate VRPM (Virtual RPM) on the lower line.  In the Menu, 
the adjustments happen in 

real time

, so if the strobe is flashing 

the user can view the effect of changing the virtual RPM. 

NOTE:  Turning the power o

 will reset the delay modes. 

8. BATTERY 

PACK

When ordered as such, the Nova-Pro comes with one two 
rechargeable Lithium Ion ba ery pack(s), external charger 
and power supply. The Ba ery Pack is shipped in a mostly 
discharged state and has tape over the terminals. 

REMOVE TAPE BEFORE USE.   

CHARGE BATTERY PRIOR TO USE. 

CAUTION: 

x

Do not store ba ery in hot loca ons. 

x

Do not expose to 

fi

re. 

x

Do not disassemble. 

x

Do not apply mechanical force. 

REMOVE Ba ery Pack from unit before storing for long periods. 

DO NOT DISPOSE of the Lithium-Ion ba eries as unsorted municipal 
waste.  The ba eries  need  to  be  RECYCLED in accordance with local 
regula ons.  The ba eries should be sent to a recycling center or  
returned to the factory using appropriate shipping methods. 

29 

 

 

 The Nova-Pro Ba ery Pack is speci

fi

cally keyed to 

fi

t in the Nova-Pro and 

Charger Base one way only.  Insert the Ba ery Pack into the Nova-Pro 
un l the clips lock into place.  To remove, squeeze clips on the Ba ery 
Pack to release from the Nova-Pro. 

8.1 Low Ba ery Func onality 

Low ba ery icon will blink when ba ery pack needs to be 
recharged.  The unit may s ll be used for a short  me. 

The Nova-Pro will display “LOBAT” and shut down when the ba ery 
pack is exhausted and must be recharged. 

8.2  Charging the Ba ery Pack 

The Nova-Pro Ba ery Pack must be 

 

removed from the Nova-Pro to be charged 
using the Nova-Pro Charging Sta on and 
power supply provided.   

CAUTION: Never a empt to charge the 
Ba ery Pack with anything other than  
the Charging Sta on and power supply  
provided with the Nova-Pro. 

The Nova-Pro Charging Station has an light emitting diode (LED) that  
indicates the state of the battery/station.  The LED indicates the following: 

Green 

On / No Ba ery or Ba ery Charged 

 Red 

Charging 

Flashing Red 

Error / Replace Ba ery 

Ba ery charge  me will be up to 6 hours depending on Ba ery Pack 
and residual charge. Once the ba ery is charged the charger will 
switch to trickle charge mode—the ba ery should be removed once 
the charge LED turns green. 

30 

LED 

Power 

Supply 

Input 

Key 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for Nova-Pro Ultra Violet UV365

Page 1: ...Nova Pro Ultra Violet UV365 UV385 Stroboscope Lamp Tachometer Instruction Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...ed to a reclama on facility for recovery of the metal and plas c components as the proper method of waste management Contact distributor for product return procedures TABLE OF CONTENTS 1 INTRODUCTION...

Page 3: ...u 21 5 6 1 NONE 22 5 6 2 PHASE 22 5 6 3 TIME 22 5 7 DELAY Menu 22 5 7 1 NONE 23 5 7 2 PHASE 23 5 7 3 TIME 23 5 7 4 VRPM 23 6 STROBE BRIGHTNESS 24 6 1 Calcula ng Blur 24 6 2 Brightness in Degrees of Ro...

Page 4: ...Table 1 Nova Pro Features 1 2 Bezel and Lens Bezel is removable to add or remove the Laser Module UV Emi ed from here 3 Laser Module Internal laser used to synch the flash to an external marker on th...

Page 5: ...h Keypad Numeric Used to directly enter precise flash rates 8 TACH icon Ac ve when Tachometer Mode is selected 9 x2 2 and arrows Used to double or halve the flash rate 10 POWER bu on Turns the unit on...

Page 6: ...Con nuous Opera on The unit can be locked in con nuous opera on by pressing the POWER bu on while squeezing the trigger Keep holding the POWER bu on as you release the trigger and the Lock icon will s...

Page 7: ...when the digit is changed if incremen ng the units digit 99 will roll over to 100 If the user does not increment or decrement a digit within 5 seconds the edit mode will be cancelled 7 Use joys ck or...

Page 8: ...00 FMP EVERY OTHER ROTATION 2 One target 3 000 FMP ONCE EVERY ROTATION 0 Two targets 6 000 FMP TWICE PER ROTATION X2 Four targets 12 000 FMP FOUR TIMES PER ROTATION X2 X2 flash each me a signal is rec...

Page 9: ...THROUGH OPTICAL INSTRUMENTS 4 4 TACH Tachometer Mode The TACH Tachometer Mode requires the Laser Module to be installed OR an external input sensor be plugged in This mode uses the Laser or External...

Page 10: ...CPT to SET none 1 2 3 RPS FPM FPS Nova Pro 500 and UVxxx Only When using an ex ternal input DOWN but ton MENU but ton POWER but ton NAVIGATIONkeypad DOWN but ton onkeypad KEY 14 SEtUP MODE STROBE MODE...

Page 11: ...e This will change the mode and exit the menu Press the POWER bu on to escape without changing the mode 5 3 Brightness BRITE Menu Refer to Sec on 8 for details on Brightness and Flash Dura on before u...

Page 12: ...hout changing the polarity press the Power bu on 19 5 4 5 BKLIT Backlight Menu This menu op on turns the backlight of the display ON or OFF Press the MENU bu on to enter the Backlight menu Use the arr...

Page 13: ...value of 600 will be displayed as 600 600 0 600 00 600 000 depending on the se ng 17 Press the MENU bu on to enter the DECPT menu The current value is shown on the top line with DECPT on the lower lin...

Page 14: ...d Jog method The op ons are NONE PHASE and TIME Press the MENU bu on to select a Jog method This will enter the sub menu for PHASE or TIME 21 5 6 1 NONE To cancel the JOG mode press the MENU bu on whe...

Page 15: ...shing the user can view the e ect of changing the RPM To exit the DELAY Menu press the Power bu on Press the Power bu on to escape back out of the setup menu 6 STROBE BRIGHTNESS The strobe s brightnes...

Page 16: ...z 25 6 3 Brightness in Pulse Dura on Brightness can also be set to a fixed duration pulse in microseconds The flash rate remains constant irrespective of the flash rate thus as the flash rate increase...

Page 17: ...respect to the trigger point 27 STOP MOTION 30 60 90 P PHASE TRIGGER POINT 30 60 90 Figure 9 Triggered Phase The Phase Delay tracks the speed of the target the strobe is con nuously compu ng the dela...

Page 18: ...ppropriate shipping methods 29 The Nova Pro Ba ery Pack is specifically keyed to fit in the Nova Pro and Charger Base one way only Insert the Ba ery Pack into the Nova Pro un l the clips lock into pla...

Page 19: ...385 nm Flash Range FPM RPM 30 to 999 999 Display 6 digit numeric and 5 digit alphanumeric LCD with touch keypad High contrast blue background white characters with backlight Accuracy Resolu on 0 001...

Page 20: ...gs Charger Power Supply Replacement power supply for use with Charging Sta on 115 230 Vac with USA UK AUS Euro adapter plugs Standard Ba ery Pack Replacement Standard Li Ion Ba ery Pack Long Life Ba e...

Page 21: ...other product lines Speed Sensors Temperature Humidity Sensors Vibra on Meters Paperless Recorders Track It Data Loggers Printed in the U S A Copyright 2017 Monarch Instrument all rights reserved 1071...

Reviews: