GB
39
Function
Default setting
Zones
Type*
1
E/E
*meaning of the settings see chapter 5.1
F-Exit Mode
time = according to the time adjusted
termination of the exit delay with
full activation
P-Exit Time
Menu item
30 seconds
exit delay time with partial activation
Confirm Mode
Off = no confirmation by the strobelight
confirmation of the activation
P-Exit Mode
time = according to the time adjusted
termination of the exit delay
with partial activation
P-Exit Sounder
Aud. = audio signal
Alarm triggering and panic button
Bell Delay
signal during the exit delay
with partial activation
Quick-Set
On = is possible
activation with the button “Quick”
Entry 1 Time
30 seconds
entry delay 1st partial time
Entry 2 Time
10 seconds
entry delay 2nd partial time
Entry delay and exit delay
Panic Mode
Aud. = siren, strobelight, speaker and buzzers
of the keypad controller respond
Ring Time
20 minutes
siren time
00 seconds
response delay of the siren
Bell Re-Arms
99 times
alarm repeats of the siren
Bell Mode
alarm triggering by actuating a
panic button
Text
Mode*
zone 1
Chime
2
Pt E/E
zone 2
Full
3
12 Hr
zone 3
Full
4
12 Hr
zone 4
Part1
5
12 Hr
zone 5
Part2
6
E/E
zone 6
Full
7
Panic
zone 7
Full
8
12 Hr
zone 8
Full
SAB (self-actuating bell) = siren without time limit
siren type
Function
F-Exit Time
30 seconds
exit delay time with full activation
Tamper Ring
Off = no alarm triggering by the siren and the strobelight
(only by the buzzers of the keypad controllers
and the speaker)
alarm triggering in case of tampering
actions of the siren and deactivated
alarm control system
Number of the events which
64 events (with date + time); a change to can be stored
256 events without time indications will not be reset*
Mode of the log
Access codes
for programming of the alarm control system
for the operators
5, 6, 7, 8 (master code 1)
1, 2, 3, 4 (however, if the code was changed to one with a
9 at the beginning, it will not be reset*)
PGM 1 Mode
SW12V = 12 V are present with activated
alarm control system
Control output PGM1
control output PGM1
Alarm Restore
Off, please do not change
not relevant for the DA-8000
Chan. 1 Mode
Fire, please do not change
not relevant for the DA-8000
Tamper Reset
Any = resetting is possible with any code
Alarm reset authorization and function with simultaneously pressing the buttons 1 + 3
alarm reset authorization in case
of tampering actions
Alert Mode
Panic = panic button
function when pressing the buttons 1 + 3
Alarm Reset
Mast = resetting by the master code only
alarm reset authorization in case of alarm
Fig. 16 Default setting
* when resetting to the default setting
Summary of Contents for security DA-8000