GB
34
Eng. (engineer)
The acoustical signalizing can in fact be terminat-
ed with a desired access code, however, the alarm
can only be reset with the button Reset after
entering the access code for programming pre-
viously (default setting: 1, 2, 3, 4).
Any
The alarm can only be reset by entering a desired
access code and pressing the button Reset sub-
sequently.
46) To confirm the authorization, press the button Yes.
The display changes to:
If the timer is started by entering another number,
it counts the time (in weeks) up to the next servic-
ing.
47) Press the button Yes. The display changes to:
It is possible to select at this menu item which
alarm type is triggered by simultaneously
pressing the numerical keys 1 and 3 at a key-
pad controller:
Panic
With this setting an alarm is immediately triggered
by pressing the keys 1 and 3 simultaneously, even
is the alarm control system is deactivated. This
function can thus be used as raid detector (panic
switch).
Fire
With this setting a fire alarm is immediately trig-
gered by pressing the keys 1 and 3 simultaneous-
ly, even if the alarm control system is deactivated.
To recognize the fire alarm, a siren connected will
sound in a pulsed way. This function can thus be
used as a fire detector.
Alert
Only with deactivated alarm control system an
alarm is triggered by pressing the keys 1 and 3
simultaneously. However, this is only signalized by
the buzzers of the keypad controllers and the
connected speaker. Thus, this function can e.g.
serve as internal emergency detector.
Off
No function is triggered by pressing the buttons 1
and 3 simultaneously.
5.6 Terminating the programming mode
Unless it is expected to enter a number as the next
operating step, independent of the actual menu level
press the button 0 so many times until an audio signal
confirms the termination of the programming mode
and the display again shows date, hour, and
<<< UNSET >>>.
5.7 Changing the access code for program-
ming
Two access codes are factory-set:
1.
Access code for activating/deactivating and call-
ing the operating menu (master code); default set-
ting: 5, 6, 7, 8 for the user No. 1. Via this code up
to eight further access codes for activating/deac-
tivating with different access authorization can be
provided (see operating instructions).
2.
Access code for programming; default setting:
1, 2, 3, 4. This can be changed as follows:
1)
The alarm control system must be deactivated.
Enter the access code for programming which is
valid at present. The display shows:
2)
Press the button No within 15 seconds, otherwise
the programming mode will be exited. The display
shows:
3)
Press the button No two more times. The display
must now show:
4)
Press the button YES. The display shows:
5)
Press the button No. The display shows:
6) Press the button Yes. The display shows:
7)
Press the button No. The display shows:
C o d e
0 0 0 0<—
C o d e
# # # #
Do You Want to..
P r o g r a m C o d e s ?
Do You Want to..
P r o g r a m C h i m e ?
Do You Want to..
Select Options ?
Do You Want to..
T e s t ?
Do You Want to..
S e t E n g i n e e r ?
A l e r t M o d e
P a n i c
Attention!
Do not change this default setting “99” (99 = timer
off), otherwise the service timer will be started. If
this has expired, the alarm control system can
only be reactivated if the timer was reset before.
For this purpose a special software and a PC are
required!
S e r v i c e T i m e
9 9
Summary of Contents for security DA-8000
Page 83: ...79...