![Monaco 2009 Knight Owner'S Manual Download Page 176](http://html1.mh-extra.com/html/monaco/2009-knight/2009-knight_owners-manual_1824573176.webp)
12
2009
K
night
Electrical Sy
stems - House - 8
Fuses:
Blade fuse comes in three sizes: Mini,
Standard and Maxi. Fuse color determines
amperage ratings. A blown fuse indicates an
over-current condition has occurred. Typically
the conductor strip in the center of the fuse is
broken, but not always, and is best verified by
use of a 12 Volt DC test light. Located atop
the blade style fuse housing are two exposed
terminals. The fuse is good if the test light
illuminates at both terminals. This may require
the circuit be activated for power to be present
at the fuse. The fuse is bad if the test light
illuminates at only one terminal.
There are three types of Circuit Breakers:
Type 1
is an automatic reset type circuit
breaker. This type of breaker may cause
component damage under a short circuit
condition. It will not damage the circuit, the
installation or present a safety risk
Type 2
is an automatic reset type circuit
breaker. Under a short circuit condition, this
type of breaker will not cause component
damage or damage to the circuit, the
installation or present a
safety risk.
Type 3
is a manual
reset circuit breaker.
This type of breaker
will open under a short
circuit condition and
must be manually reset.
BATTERIES - HOUSE
House batteries are designed for use with
12 Volt DC operated lights, appliances and
inverters.
House Battery Types:
Liquid Lead Acid (LLA)
Deep Cycle Batteries:
Deep cycle batteries are a type of Liquid
Lead Acid (LLA) battery. Deep cycle batteries
are best suited for use with 12 Volt operated
lights, appliances and inverter/converters.
Deep cycle batteries are designed to have a
majority of their capacity used before being
recharged.
NOTE
Tap water contains minerals which can
alter chemistry and ruin the battery.
Use only distilled water when refilling
the LLA battery.
Battery Slide-Out Tray (Optional)
The slide-out battery tray is secured in place
by a locking mechanism at the front of the
tray. To slide the tray out, pull up on the two
handles to unlock then pull tray out until it
stops. To secure the battery tray, push it back
in until the tray latches.
060359b
Large amperage
circuit breaker
ATC Fuse
060086B
Exposed fuse terminals.
060086c
Blade fuse guide
Mn
standard
Max
Black
1
gray
2
2
25
violet
3
3
Pink
4
4
Tan
5
5
70
Brown
7 1/2
7 1/2
35
red
10
10
50
Blue
15
15
60
yellow
20
20
20
Clear
25
25
80
green
30
30
30
Blue-green
35
Orange
40
40
Mini, Standard and Maxi fuse colors and
amperage ratings
a
B
c
d
e
Quarter is used for size comparison of fuses.
080528e
A. Manual Reset Circuit Breaker
B. Auto Reset Circuit Breaker
C. Standard Fuse
Representation of various fuses and a circuit breaker
D. Mini Fuse
E. Maxi Fuse
060352
Pull up on handles
Summary of Contents for 2009 Knight
Page 12: ......
Page 14: ......
Page 16: ......
Page 46: ...42 2009 knight Driving Safety 2 Weighing Procedure Worksheet Example Worksheet 020255b conv...
Page 47: ...43 2009 knight Driving Safety 2 Weight Record Sheet Actual Worksheet 020255b 020263...
Page 52: ...48 2009 knight Driving Safety 2 Notes...
Page 152: ...148 2009 knight Water Systems 6 Notes...
Page 182: ...178 2009 knight Electrical Systems House 8 Notes...
Page 201: ...197 2009 knight Electrical Systems Chassis 9 engine no start flow chart...
Page 202: ...198 2009 knight Electrical Systems Chassis 9 Notes...
Page 251: ...247 2009 knight Chassis Information 10...
Page 260: ...256 2009 knight Index Notes...