-36-
Revision 6/F3590
©
Moffat Ltd, February 2005
Electrode
nuts
Transformer
Figure 6.3.22
6.3.18 IGNITION BOX
6.3.19 IGNITION ELECTRODES
1) Remove burner access panel (refer 6.2.4).
2) Remove the ignition electrode assembly
by unscrewing two screws securing
electrode bracket to the burner box, and
withdrawing the electrode assembly.
IMPORTANT:
ENSURE ELECTRODE
LEAD CONNECTIONS ARE FULLY
INSULATED TO AVOID SHORTS IN THE
HIGH TENSION CIRCUIT.
3) Disconnect wires (earth at sensor, flame
sensor and spark electrode at lead
connections) from electrodes requiring
replacement.
4) Unscrew screws/nuts securing electrodes
and remove from bracket.
5) Replace and reassemble in reverse order.
Two
screws
Figure 6.3.23
6.3.17 24 VOLT TRANSFORMER
(USA / CANADA UNITS ONLY)
1) Remove the right hand panel (refer 6.2.2).
2) Remove the wires from the transformer,
noting their positions.
3) Remove the two screws securing the
transformer to the oven.
Figure 6.3.20
4) Replace transformer and re-assemble in
reverse order.
NOTE:
Ignition box may differ from that
pictured here. Replacement procedure is
however identical.
Flame sensor screw
Figure 6.3.21
1) Remove the right hand side panel (refer
6.2.2).
2) Remove two screws securing the ignition
box to the mounting plate.
3) Transfer wires from old ignition box to the
new one.
4) Secure new ignition box to the oven with
two screws.