-35-
Revision 6/F3590
©
Moffat Ltd, February 2005
1) With baffle removed undo the centre nut.
NOTE:
LH thread - Turn clockwise to
loosen.
6.3.15 MOTOR
6.3.14 FAN
6.3.13 SPRAY NOZZLE
1) Inside the oven remove the RH side fan
baffle, then unscrew the spray nozzle.
Note:
When replacing a motor on a unit
manufactured before February 2004 refer to
appendix D.
1) Remove side service panel (refer 6.2.2)
2) Remove fan (refer 6.3.14) and then
remove the wires that go to the motor.
Figure 6.3.17
Spray nozzle
2) Clean or replace as required, ensuring
debris free on re-assembly.
3) Ensure that the spray nozzle is installed in
the vertical position.
Figure 6.3.15
Screws (3)
60 Hz
Terminal
50 Hz
Terminal
Earth /
Ground
Neutral
Figure 6.3.16
2) Replace and re-assemble in reverse
order.
Centre nut
6.3.16 OVERTEMP THERMOSTAT
(UK UNITS ONLY)
1) Open control panel (refer 6.2.1)
2) To reset, firmly press reset button.
Figure 6.3.18
4) Remove wires from overtemp.
Figure 6.3.19
5) Open oven door, remove racks and fan
baffle rack. Loosen two screws securing
thermostat phial bracket.
6) Withdraw old overtemp thermostat phial
through side of oven.
7) Remove fibreglass sleeving from old
thermostat and fit to the replacement
thermostat.
8) Replace overtemp and re-assemble in
reverse order.
WARNING: OVERTEMP IS LIVE.
ISOLATE UNIT FROM THE POWER
SUPPLY BEFORE RESETTING.
3) To replace overtemp thermostat, remove
the two screws securing overtemp to its
bracket.
3) Undo the three screws holding the motor
in place (from the outside) and remove
motor.
4) Replace and re-assemble in reverse
order.
5) Ensure wire connections are correct to the
voltage supply—60 Hz / 50 Hz (fig 6.3.17)
Thermostat phial
bracket
Overtemp
bracket