Device Description MC-HPG-2x0
Display PLC
MC-HPG-2x0
Display, backlight, contrast
9
D
ISPLAY
,
BACKLIGHT
,
CONTRAST
9.1 C
ONTRAST
The contrast voltage is temperature-compensated and can be adjusted in
the EPAM visualization software.
9.2 B
ACKLIGHT
The backlight has three settings (0, 50 and 100%) which can be selected in
the EPAM visualization software.
10 D
IAGNOSTICS
The following optical and acoustic diagnostic options are available:
Symptom
Possible cause and solution
Signal on power on
- Acoustic signal:
- 2x short
Touch controller OK
- low-low-high
Battery flat, BIOS has changed or rejected a setting
Device does not start,
screen dark or error
messages during startup
- - Check power supply/fuse faulty (+5V LED not lit)
- Hard disk controller 1 failure
CompactFlash with Runtime System MC-HPG-2x0 not inserted (
Section
5.2).
Date/time incorrect
Insert or replace battery ( Section 5.3)
Screen dark or light
Backlight/contrast incorrectly set
Reload EPAM project with Delete INI Files option
Touch not functioning
- - Hardware faulty (no acoustic signal after power on)
- Too many IR channels interrupted Clean touch
Ethernet connection faulty
- - Incorrect Ethernet cable fitted (crosslink/direct).
The LINK LED is lit when the connection is correct
The ACT LED is lit (flashing during transfer) with a correct data transfer
- Incorrect/invalid IP address set
The current IP address is shown during startup at the bottom right of the
screen
Refer to the XSoft engineering software documentation
for other diagnostics options.