background image

© MOBATIME 

51 / 124 

801214.10 

E-mail configuration page 2: 

 

   DTS 4160.grandmaster   Moser-Baer AG 

   ==================================== 

 

   MAIL CONFIGURATION                           Page 2 

   11 Authentication mode                       0 

   12 User name 

   13 Password 

 

   98 Return and save 

   99 Return and discard changes 

 

   Enter desired menu number> 

 

Path: 2 Configuration 

 3 Alarms 

 2 E-Mail [Enter]

 

11.  Authentication mode:  

0 = off (sender e-mail address used for authentication) 
1 = auto (tries CRAM-MD5, LOGIN- PLAIN in this sequence) 
2 = PLAIN 
3 = LOGIN 
4 = CRAM-MD5 

12.  User name (only for authentication mode 1-4) 

13.  Password (only for authentication mode 1-4) 

Press ENTER to change to page 1. 

 

Format of an error message via E-mail: 

Event <Alarm 03 set: Power failure 1> 
Time <11:26:45 10.01.07> 

Hostname <DTS4160 (10.241.0.30)> 

 

MOBA-NMS:

 Tab: Alarm, Frame: E-Mail 

 

Summary of Contents for 122031

Page 1: ...AND INSTRUCTION MANUAL DTS 4160 grandmaster Network Time Server and Master Clock Important Note This Manual is applicable for Firmware version 2018 11 27 and newer For older Firmware version please u...

Page 2: ...omposed with the utmost care in order to explain all details in respect of the operation of the product Should you nevertheless have questions or discover errors in this Manual please contact us 3 We...

Page 3: ...Installation 15 6 Operation 16 7 Updates 70 8 Time administration 76 9 SNMP 89 10 Redundant Power supply 93 Appendix A Connection diagrams 94 B Time zone table 103 C Alarm list 105 D Troubleshooting 1...

Page 4: ...48 6 5 19 Alarm relay 48 6 5 20 Alarm mask 49 6 5 21 E mail 50 6 5 22 SNMP traps 52 6 5 23 General settings 54 6 5 24 Network 55 6 5 25 Link aggregation LAG 59 6 5 26 IPv4 static routing 60 6 5 27 VLA...

Page 5: ...a 98 A 3 2 Installation of the lightning protection 98 A 3 3 Distance between antenna and DTS 4160 99 A 3 4 Inline Amplifier 100 A 4 Plug in spring terminals 102 B Time zone table 103 C Alarm list 105...

Page 6: ...eference clock PRC Grandmaster and Timeserver for the high accurate synchronization of various equipment s and for the use in large network environments It receives time information from GPS An intell...

Page 7: ...installation site To avoid any operating problems keep the device away from moisture and avoid dust heat and direct sunlight Do not use the device outdoors The device is designed for 19 racks and sho...

Page 8: ...nnot rectify this problem yourself 2 2 Cleaning Please make sure that the device remains clean especially in the area of the connections the control elements and the display elements Clean your device...

Page 9: ...f various equipment s and for the use in large network environments It can be synchronized over GNSS PTP High Precision DCF and E1 Equipped with a Rubidium Oscillator it has very high holdover accurac...

Page 10: ...4160 grandmaster Rubidium oscillator G813 compatible 122033 3 6 DTS Distributed Time System DTS Distributed Time System is a system developed by Moser Baer AG to distribute time information to decentr...

Page 11: ...e set as required For DTS devices all communication is conducted over SNMP V3 The SFTP protocol is used for broadcasting files Overview of MOBA NMS functions for DTS devices and network clocks automat...

Page 12: ...OK No power supply Alarm Red On Off The alarm relay signalizes an alarm No active alarms Sync Green On Off DTS 4160 is synchronized to the time source No synchronization to the time source No output...

Page 13: ...r Status Description LAN SFP control lamps Upper Yellow Blinking Off Network activity No activity Lower Green On Off Link 100 Mbit 1 Gbit No Link LAN RJ45 control lamps Left Green On Off Link 100 Mbit...

Page 14: ...dress LAN 2 IPv6 address LAN 3 Power Supply 1 Power Supply 2 Alarm summary Current alarms The display can be operated by means of the corresponding Display button First press the button briefly Switch...

Page 15: ...ng appears on the display during the booting procedure the display is dark and empty The display starting remains until the time of output to the lines The duration depending on the configuration is 1...

Page 16: ...Changing the password see chapter 6 5 21 General settings Only one menu can be open at any time The first menu started has priority The menu is automatically closed after 15 min without operation and...

Page 17: ...tion to the selected menu items are displayed in the response line The input line shows the current input values or options possible The status line only appears when an information has to be displaye...

Page 18: ...terminal menu and designated accordingly Example The terminal menu Configuration Alarms can be found in MOBA NMS under the tab Alarms Configuration example of a DTS 4160 grandmaster For further detail...

Page 19: ...Status menu The status menu consists of 2 pages Status menu page 1 DTS 4160 timecenter Moser Baer AG CLOCK STATE Page 1 2 1 Alarm state 2 Alarm history 3 Time state 4 Time source 5 GNSS 6 Info networ...

Page 20: ...em information display internal status regulation voltage of the oscillator This information is for support purposes only 8 Product information like serial number firmware version etc 9 All respective...

Page 21: ...Time source current time source Last time info from source time of the last information from source Offset to source offset to source source system time Jitter of the source current jitter Quality of...

Page 22: ...MOBATIME 22 124 801214 10 MOBA NMS Tab Overview Frame Time time state...

Page 23: ...sured offset 0ns Stability Deviation 12ppb Leap status No leap second detected Date of next leap second Adj direction None None 99 Return Enter desired menu number Path 1 Status 4 Local source enter 2...

Page 24: ...ice Ping DTS 4160 grandmaster Moser Baer AG NETWORK PING 1 Select LAN interface 1 4 1 2 Select IP configuration 1 2 1 3 Destination IP address 192 168 0 20 5 Execute ping command 99 Return Enter desir...

Page 25: ...andmaster Moser Baer AG PTP INFO DEVICE LAN2 IP1 PAGE 1 3 State MASTER Offset to Master 0ns PathDelay E2E 0ns PathDelay P2P 30ns ClockClass 6 ClockAccuracy 0x21 TimeSource 0x20 99 Return Enter desired...

Page 26: ...time source time keeping etc See chapter 6 5 8 Time handling 3 Alarm settings alarm relay e mail SNMP See chapter 6 5 16 Alarm 4 General settings of the DTS 4160 language time zone for alarms and dis...

Page 27: ...Serial lines 4 IRIG outputs 5 E1 signals 6 NTP slave clock time zone server 99 Return Enter desired menu number Path 2 Configuration 1 Outputs 1 DCF Output see chapter 6 5 2 2 Pulse Frequency output...

Page 28: ...requency output 10 MHz output The DTS 4160 is equipped with 2 pulse frequency interfaces The signals are available on the BNC connectors Pulse and 10 MHz In addition 1 of the pulse frequency outputs i...

Page 29: ...out 1 1 Select mode Line switched off on 2 Select time zone see chapter 6 5 30 Time zone selection 3 Com mode 1 send RS 232 receive is not enabled 2 send and receive RS232 3 send and receive RS485 4 s...

Page 30: ...3 Serial line Serial out 1 8 Telegram file The copy procedure of telegram files is explained in chapter 7 10 Copying Telegram files to the DTS MOBA NMS Frame Serial e g Interface 1 click on Change 1 T...

Page 31: ...the output voltage level 2000 4000 mV The defined voltage corresponds to the expected output amplitude when power matching impedance matching with a load of 50 Ohms is fulfilled The output voltage is...

Page 32: ...G NTP SLAVE CLOCKS AND TIME ZONE SERVER 1 Mode 0 off 1 NTP 2 NTP TZ 3 TZ 4 TZ poll 0 2 Multicast address 3 Multicast port 65534 4 Pollinterval for NTP 0 5 Packet time to live hops 1 6 Repeat time to s...

Page 33: ...h the same Multicast IP address redundancy then the first time server has to be configured with a small pollinterval e g 2 4 sec and second time server with a large pollinterval min 100 x larger e g 9...

Page 34: ...e server 1 Time zone server in Unicast mode Set Mode to Time zone server on req 2 Click on Time zones to define the list of time zones sent to slave clocks 3 In the list of time zones you can define u...

Page 35: ...rce Time adjustment configuration see chapter 6 5 10 Time adjustment Time keeping Redundant operation see chapter 6 5 11 Redundant operation NTP Authentication see chapter 6 5 12 NTP For setting the t...

Page 36: ...inutes 1min 2 160min default 1 Error loss of time source TO 3 DTS stratum 0 Stratum is automatically calculated according to the time source 1 15 Stratum DTS 4160 is set by means of the description in...

Page 37: ...de manual 98 Return and save 99 Return and discard changes Enter desired menu number Path 2 Configuration 2 Time handling 1 General source setting Source configuration 1 6 Source PriorityX 0 NONE 1 GN...

Page 38: ...ustment only therefore parameter is not configurable 2 Maximum catch up speed Depending on installed Oscillator type A OCXO 25ns s B DOCXO 4ns s C Rubidium 1ns s 3 Time core type Standard 0 0 255 unus...

Page 39: ...iption of redundant operation see chapter 8 14 Redundant operation of 2 DTS 4160 grandmaster 6 5 12 NTP Up to 4 multicast or broadcast addresses can be configured DTS 4160 timecenter Moser Baer AG NTP...

Page 40: ...Export keys to ram directory The current ntp keys file is written in the directory ram 3 Select the trusted keys separated by space 4 Select the request key 5 Select the control key 6 Set the auto ke...

Page 41: ...roadcast ENTER without entering an address will delete the entry 2 Interval for sending out the NTP information in seconds The interval is rounded after the entry to NTP standard which only permits va...

Page 42: ...Master 200ns 98 Return and save 99 Return and discard changes Enter desired menu number Path 2 Configuration 2 Time handling 5 PTP function 5 PTP slave settings 1 LAN interface for the PTP time source...

Page 43: ...Moser Baer AG PTP CONFIGURATION config 1 PAGE 2 3 8 Domain 0 9 LOG Announce interval 1 2 second 10 LOG Sync interval 0 1 second 11 LOG Delay Request interval 0 1 second 12 Announce TO 3s 13 Sync TO 3s...

Page 44: ...ity 128 98 Return and save 99 Return and discard changes Enter desired menu number Path 2 Configuration 2 Time handling 5 PTP function 1 PTP config 1 Enter Enter 15 Master Only 0 False 1 True default...

Page 45: ...Time handling 6 GNSS settings 1 Total Antenna delay ns 0ns 0ns 1000ns 2 Fixed Position Mode FPM 0 off 1 on 0 3 FPM minimum observation time sec 86400sec 0s 604800s 1 week 4 FPM minimum position accur...

Page 46: ...f the hardware delay We recommend that a second source is used to calibrate the DCF Only a high precision DCF signal e g from another DTS 4160 4210 or from GPS 4500 or GNSS 3000 is supported The recei...

Page 47: ...TER 2 Correct time in ns backwards Range 1 000 000 000ns Time is set with ENTER 3 Leap second mode 0 off 1 Additional second will be inserted at entered time Is set to 0 off after inserting the leap s...

Page 48: ...see chapter 6 5 23 6 5 19 Alarm relay DTS 4160 grandmaster Moser Baer AG ALARM CONFIGURATION 2 1 Alarmmask for relay 98 Return and save 99 Return and discard changes Enter desired menu number Path 2 C...

Page 49: ...t14 GNSS synch lost Bit15 Time source big offset Enter alarm number to alter mask Press ENTER for next part 99 to leave Path 2 Configuration 3 Alarms 1 Alarm relay 1 Alarm mask for relay Display of al...

Page 50: ...20 Alarm mask Changes are stored or reset on the overlying menu page MAIL CONFIGURATION 3 IP address of the mail server e g 10 249 34 5 ENTER without entering an address will delete the entry 4 Mail s...

Page 51: ...on 3 Alarms 2 E Mail Enter 11 Authentication mode 0 off sender e mail address used for authentication 1 auto tries CRAM MD5 LOGIN PLAIN in this sequence 2 PLAIN 3 LOGIN 4 CRAM MD5 12 User name only fo...

Page 52: ...pplies to alarm and alive traps 2 Alarm mask for SNMP trap messages see chapter 6 5 20 Alarm mask Changes are first stored or reset on the overlying menu page SNMP TRAP CONFIGURATION 3 Trap community...

Page 53: ...rn and save 99 Return and discard changes Enter desired menu number Path 2 Configuration 3 Alarms 3 Traps 4 Configuration of destination 1 1 Address of the evaluation system e g 10 240 0 9 ENTER witho...

Page 54: ...urn and discard changes Enter desired menu number Path 2 Configuration 4 General Device Display Language 2 Setting the time zone for the display and also all alarm logs e mail and SNMP See chapter 6 5...

Page 55: ...5 124 801214 10 6 5 24 Network DTS 4160 grandmaster Moser Baer AG NETWORK INTERFACES 1 LAN 1 2 LAN 2 3 LAN 3 4 LAN 4 99 Return Enter desired menu number Path 2 Configuration 5 Network MOBA NMS Tab Net...

Page 56: ...ost names may only contain letters capitals or small letters and numerals 0 9 In addition the minus sign may also be used as long as it is not at the end Everything else is not permitted 5 Set domain...

Page 57: ...ration 5 Network 1 LAN 1 Enter 11 Configuration of link aggregation 12 VLAN configuration for IP1 select predefined VLAN config 1 16 0 off See chapter 6 5 27 VLAN configuration 13 VLAN configuration f...

Page 58: ...d via this point Notice DHCP on if no DHCP server is available leads to longer start up time approx 60 sec of the DTS 2 8 Set IP address subnet mask gateway and DNS server Format 10 240 98 7 Network c...

Page 59: ...tion on or off 2 LAG Mode 0 Round robin fault tolerance and load balancing 1 Active backup only one slave in the bond is active fault tolerance 2 Balance XOR fault tolerance and load balance 3 Broadca...

Page 60: ...aster Moser Baer AG NETWORK IPV4 STATIC ROUTING LAN 1 1 IP1 network destination 1 Prefix 0 0 0 0 24 2 IP1 network destination 2 Prefix 0 0 0 0 24 3 IP2 network destination 1 Prefix 0 0 0 0 24 4 IP2 ne...

Page 61: ...rn and discard changes Enter desired menu number Path 2 Configuration 6 VLAN configuration 1 VLAN config 1 1 Name of the VLAN Max 64 characters 2 Setting the VLAN ID 1 4094 3 Priority Code Point accor...

Page 62: ...n DTS 4160 grandmaster Moser Baer AG NETWORK SERVICES 1 telnet on 2 ftp on 3 ssh scp sftp on 98 Return and save 99 Return and discard changes Enter desired menu number Path 2 Configuration 7 Services...

Page 63: ...Notice To send out MIB 2 traps the trap community and the destination address must at least be configured in menu 2 Configuration 3 Alarms 3 Traps See also chapter 6 5 23 SNMP traps 2 Alarm mask for...

Page 64: ...oup membership for GET PUT Standard rwmobatime Notice Each configuration change leads to a restart of the DTS SNMP Agent 6 5 31 SNMP V3 DTS 4160 grandmaster Moser Baer AG SNMP V3 CONFIGURATION 1 User...

Page 65: ...uration 1 User 1 config uration DTSUser1 1 Password for authentication MD5 and privacy DES 8 40 characters 2 Minimal security level 1 noauth no authentication 2 auth only authentication 3 priv authent...

Page 66: ...2 4 4 Exclude OID 1 2 5 Exclude OID 2 2 6 Exclude OID 3 2 98 Return and save 99 Return and discard changes Enter desired menu number Path 2 Configuration 8 SNMP 6 SNMP V3 security configuration 3 Acce...

Page 67: ...e 19 9 Tokyo Enter requested time zone Press enter for next part ESC to leave Display of all the DTS 4160 time zones 100 over several pages The pages can be scrolled through with ENTER A time zone can...

Page 68: ...e a software update files must first be put onto a USB stick and this stick must be connected to the DTS 4160 See chapter 7 Updates The command always leads to a restart of the DTS 4160 even if no fil...

Page 69: ...can be released by clicking with right mouse button to the device and selecting Commands The Commands menu can be also opened by clicking on Command Icon The following functions can be started via Me...

Page 70: ...4160_dts4210rootfs ubifs dts4160_dts4210cfg ubifs dts4160_dts4210uImage dts4160_dts4210devicetree dtb Additionally the file dts4160_dts4210check md5 must exist all file names are case sensitive Steps...

Page 71: ...re the versions should be verified after the update 7 4 Updating images via USB Possible images are dts4160_dts4210u boot dts4160_dts4210app ubifs dts4160_dts4210rootfs ubifs dts4160_dts4210cfg ubifs...

Page 72: ...message Update in progress appears and at the same time Please wait is shown in the command line All applications are copied The DTS 4160 is automatically restarted on completion of the update The Te...

Page 73: ...can also enter ftp dts 10 241 0 5 ram Establish connection with IPv6 The address must be written in brackets e g with Explorer enter ftp dts fd03 4432 4646 3454 2000 Notice The file has to be copied...

Page 74: ...elements that are to be saved In case of doubt select everything 4 Click button Next 5 Indicate destination file by clicking the Browse button 6 Optionally enter a free backup comment E g reason for t...

Page 75: ...bed procedures telegram files can be copied via FTP or USB stick to the DTS 4160 The copy procedure can be started on DTS 4160 by selecting the menu 3 Maintenance 8 Copy telegram files and press ENTER...

Page 76: ...LAN Multicast Devices DCF Outputs UTC Master Clock NTP A B C D Display Operation Error report F PTP GPS SyncE External DCF Timesource Time Zone Entry Time Zone Entry Time Zone Entry Time Zone Entry Ti...

Page 77: ...he available time sources 1 On system startup the DTS waits until the oscillator reaches stable state 2 Then it waits for an available source to set system time usually it uses the first source that i...

Page 78: ...MOBATIME 78 124 801214 10...

Page 79: ...longer it takes to reach high holdover accuracy Holdover accuracy increases over time hence the longer synchronized the higher is the accuracy in holdover Short term time frequency stability When the...

Page 80: ...ep 8 min step Stratum increase is stopped at configured Stratum limit E g the Stratum timeout is 2 hours increasing of the Stratum every 8 minutes the Stratum limit is set to 12 These means after 8 mi...

Page 81: ...ted deviation this means the more stable a source the better its rating DTS will switch immediately to priority 3 source E1 because its deviation is lower than the one of PTP meaning in this scenario...

Page 82: ...ared when the leap second mode is changed to no leap second Manual user input To ensure that the leap second adjustment process starts at the exact time the leap second may be configured manually In t...

Page 83: ...of dates of the UTC second markers will be as the following Example end of the year 1 Second December 31 23h 59m 59s December 31 23h 59m 59s January 01 00h 00m 00s 1 Second December 31 23h 59m 57s Dec...

Page 84: ...will not be used for synchronization The DTS 4160 must be correspondingly configured to be able to use NTP authentication chapter 6 5 12 NTP The NTP service of the other equipment e g server PC must...

Page 85: ...udel edu mills proto html or on the NTP homepage http www ntp org Autokey is currently defined in an IETF draft https tools ietf org html draft ietf ntp autokey 08 The configuration of Autokey is expl...

Page 86: ...ed HDB3 coding format Features Supports CRC4 DTS 4160 meets the following standards G 813 when OCXO MV197 B5G is installed G 812 when OCXO MD 1731 DAT is installed G 811 when Rubidium is installed and...

Page 87: ...econds Starting the devices with fibre optic connection The devices work out among themselves which is the master normally the one synchronized first Both devices are always synchronized from GPS Both...

Page 88: ...TP Clients use BMCA Best Master Clock algorithm RTC It is recommended to not use the RTC Notice If redundant mode is in use either leave network settings of port 4 on default values or at least switch...

Page 89: ...ent supports user validation authentication MD5 and encoding encryption DES MIB II values like sysDescr sysContact sysName or sysLocation can only be modified over the DTS menu but not via SNMP The fo...

Page 90: ...n from the MIB files Example Management System DTS Put dts4160FTPMode 1 Variable is set to 1 internally Put dts4160NetServicesConfigCmd 1 Configuration group is assumed Sends dts4160ConfigChanged Noti...

Page 91: ...nfigChangedTime TimeTicks 4 Bytes dts4160NetworkLAGIFEntry dts4160NetworkIPCfgConfigChangedTime TimeTicks 4 Bytes dts4160NetworkIPCfgEntry dts4160NetworkVLANConfigChangedTime TimeTicks 4 Bytes dts4160...

Page 92: ...4 Bytes Contains the internal system status 66309 dts4160SysAlarms Byte Array 8 Bytes 64 Bit Alarm flags 1 Byte Bit 0 7 2 Byte Bit 8 15 8 Byte Bit 56 63 FFF870FF FFFFFFFF 5 Byte 2 Byte 1 Byte 9 3 6 Al...

Page 93: ...a full surveillance of the inputs following variants are possible Supply1 Supply2 Variant 1 Mains supply DC in 1 Variant 2 Mains supply DC in 2 Variant 3 DC in 1 DC in 2 Supply is checked once per min...

Page 94: ...of the connection 3m Connections between female connector 1 SUB D 9 1 and female connector 2 SUB D 9 2 SUB D 9 1 SUB D 9 2 Receive Data 2 3 Transmit Data Transmit Data 3 2 Receive Data Data Terminal...

Page 95: ...ower supply GND 3 DC in 2 power supply Input for external DC supply 24 28V Ground 4 DC in 2 power supply GND 5 Alarm relay Alarm contact open when alarm is active Max load 30 W 30 VDC or 1A or 60 VA 6...

Page 96: ...her DTS 4160 Multiple IP addresses 802 3ad LAG 802 1Q tagged VLAN 802 1p prioritized VLAN LAN1 LAN2 LAN3 LAN4 Section Connection Description E1 Interface BNC female RX E1 signal Receive 75 Ohms future...

Page 97: ...tput current loop passive Umax 30VDC Ion 10 15mA Ioff 1mA 20VDC Puls Out CL IRIG Digital OUT AFNOR A C IRIG B1xx and DCF FSK output for IRIG line digital 50 Ohms TTL IRIG Digital GND Serial 1 2 RS232...

Page 98: ...ion with open view to the sky The minimum viewing angle for correct functioning is 90 With a viewing angle of less than 90 it is to be expected that the device will not be able to receive a signal at...

Page 99: ...alculated with the minimum amplifier gain The attenuation of the lightning protector is 0 2 dB The maximum cable length for specific cable types manufacturer Huber Suhner are listed in the table below...

Page 100: ...G 58 C U Cable A plus Cable B should not be longer than 37 m Cable C should not exceed 26 m Inline Amplifier Tallysman TW127 Nominal gain 25 dB 4 0 dB typ Impedance 50 Ohms Noise figure 2 dB typ Opera...

Page 101: ...ture range 40 C to 85 C Weight 650g without mounting kit Humidity 95 For complete antenna data sheet please see http www antenna com apg_products cgi id_num 11209 Lightning protection 3402 17 A Huber...

Page 102: ...table on the previous page Minimal amplifier gain 19 2 dB Maximum noise figure 1 5 dB Polarization Right hand circular Operating DC voltage 5V Max current 100mA with inserted inline amplifier 85mA A...

Page 103: ...amabad Karachi Yekaterinburg 5 No 15 Mumbai Kolkata Chennai New Delhi Colombo 5 5 No 16 Astana Thimphu Dhaka Novosibirsk 6 No 17 Bangkok Hanoi Jakarta Krasnoyarsk 7 No 18 Beijing Hong Kong Singapore T...

Page 104: ...o be defined manually in the user time zone table entries 80 99 Legend UTC Universal Time Coordinate equivalent to GMT DST Daylight Saving Time DST Change Daylight Saving Time changeover Standard DST...

Page 105: ...t Big offset to time source detected check time source 16 Time source fail stratum Stratum too high check time source 17 Failure time source TO No time information from the selected time source within...

Page 106: ...heck serial time zone configuration 40 serial line2 Tele file invalid See alarm bit 38 See alarm bit 38 41 serial line2 Wrong time zone See alarm bit 39 See alarm bit 39 42 Error bit42 Not used 43 Err...

Page 107: ...ously After initial operation it may take up to 7 days until optimal accuracy is reached with GPS reception Time correction was carried out manually 5 System software update The system software can be...

Page 108: ...e C See chapter E 2 Syntax of the telegram configuration file Telegram time The telegram always contains the time information for the next second for periodical telegram output The telegram content is...

Page 109: ...output sequence The formats and variables available can be seen below TS d d String with Format information TV var1 var2 Variables list Control and special characters String beginning end xFE h FE By...

Page 110: ...ble in ASCII 0 9 A F 1B Definitions CHS Sum of all bytes up to CHS AND h FF XCH XOR link of all bytes up to CHS e g time telegram with following format 36 ASCII characters Date tt mm yy Time hh mm ss...

Page 111: ...2 9 n 2 Quit no telegram output n 3 Telegram output immediately singly n 4 Telegram output at the next second singly n 5 Telegram every second n 6 Telegram every minute n 7 Telegram hourly n 8 Telegr...

Page 112: ...nt no announcement announcement 2 entries AK 0 1 Text table season status 0 no announcement winter 1 announcement winter 2 no announcement summer 3 announcement summer 4 entries ST A B C D Text table...

Page 113: ...OpenSSL SSL Lib 1 0 2g BSD style LICENSE OpenSSH SFTP server 7 9p1 BSD LICENCE dropbear SSH server 2018 76 MIT style Free party BSD LICENSE wide dhcpv6 DHCPv6 client 20080615 Free COPYRIGHT zlib Comp...

Page 114: ...GPS to SyncE G 811 G 812 G 813 compatible GPS to E1 G 811 G 812 G 813 compatible depending on used oscillator Notice NTP reception DTS 4160 as server to external NTP clients can be influenced by the n...

Page 115: ...802 1p prioritized VLAN 2 VLANs per port can be defined max 8 VLANs LAG Available for LAN ports 2 3 802 3ad only port 2 has to be configured 3 Network interfaces 100 1000BaseT Data transmission rate A...

Page 116: ...ond possible 3 different electrical outputs with the same signal passive current loop output opto coupler Imax 10 mA Umax 50 VDC RS422 BNC connector 50 Ohms no load 5 V with 50 Ohms load 2 5 V 10MHz o...

Page 117: ...DTS Link Plug in socket for mini GBIC module GigaBit Interface Converter 1000Mbps 3 3V with LC connector Recommended module for Multimode fibres D Link DEM 311GT SX 850 nm Maximal cable length depends...

Page 118: ...DES Data Encryption Standard 84 DHCP 58 DHCPv6 58 Display 14 DST 104 DTS Distributed Time System 10 DTS Link 39 87 117 E E1 output 86 116 E1 settings 46 E1 signals 32 E mail 50 116 F Factory settings...

Page 119: ...9 115 SNMP alarm notification 92 SNMP alive notification 92 SNMP notification 90 SNMP operation 90 SNMP access configuration 66 SNMP configuration 52 63 SNMP traps 52 90 SNMP user configuration 65 SNT...

Page 120: ...MOBATIME 120 124 801214 10 I Connection table to fill in Line Type Description Example Line Type Description DCF DCF out DCF for master clock ETC1...

Page 121: ...MOBATIME 121 124 801214 10...

Page 122: ...MOBATIME 122 124 801214 10...

Page 123: ...MOBATIME 123 124 801214 10...

Page 124: ...h www mobatime ch MOSER BAER SA EXPORT DIVISION 19 ch du Champ des Filles CH 1228 Plan les Ouates Tel 41 22 884 96 11 Fax 41 22 884 96 90 export mobatime com www mobatime com MOSER BAER AG Spitalstras...

Reviews: