Model: FKECOD
Size
615
621
115
121
215
221
Voltage (V)
400
Connected load (kW)
10.4
20.9
15.9
30.5
31.7
60.9
Fuse (A)
3 x 16
3 x 35
3 x 25
3 x 50
3 x 50
3 x 100
Voltage (V)
415
Connected load (kW)
11.2
22.5
17.1
32.8
34.1
65.5
Fuse (A)
3 x 16
3 x 35
3 x 25
3 x 50
3 x 50
3 x 100
Voltage (V)
440
Connected load (kW)
10.4
20.9
15.8
30.5
31.5
60.9
Fuse (A)
3 x 16
3 x 35
3 x 25
3 x 50
3 x 50
3 x 100
Voltage (V)
480
Connected load (kW)
12.3
20.9
18.9
32.6
37.6
65.1
Fuse (A)
3 x 16
3 x 35
3 x 25
3 x 50
3 x 50
3 x 100
Soft water connection
Type of water
Soft water, cold
Carbonate hardness
CaCO
3
(mmol/l (°dH))
< 0,9 (5)
Chloride Cl (mg/l)
< 50
Iron Fe (mg/l)
< 0.1
Connection pressure (kPa
(bar))
200 (2) — 600 (6)
Connection (")
R 3/4
Tap water connection
Type of water
Tap water, cold
Carbonate hardness
CaCO
3
(mmol/l (°dH))
< 4 (22)
Connection pressure (kPa
(bar))
200 (2) — 600 (6)
Connection (")
R 3/4
Water consumption for steaming
Soft water (l/h)
16
21
18
24
36
48
Water consumption for Combisteaming
Soft water (l/h)
3,5
4,6
4
5,3
8
10,6
Water consumption for WaveClean cleaning program
Soft water (l)
3
Tap water (l)
32
Wastewater connection
Wastewater type
Dirty water, maximum 80 °C
Connection to unit (mm)
50
Maximum length (m)
1