Connecting the unit
32
Installation instructions
Requirement
Unit not live
Power connection cable not live
Unit matched to the connection voltage
Side wall open
1. Route the power connection cable into the unit through the cable
gland.
2. Connect the power connection cable in accordance with the wiring
diagram.
3. Secure the power connection cable with cable ties.
4. Tighten the cable gland securely to provide strain relief.
5. Close the housing (see "Opening and closing the housing").
6. Fill out the Commissioning report.
6.2.3 Connecting the power optimisation system
DANGER
Risk of personal injury and physical damage from electric
shock
•
Prior to working on the unit, ensure that the unit has been
disconnected from the mains.
•
Do not operate the unit with the housing open.
DANGER
Risk of personal injury and physical damage from electric
shock
•
Before connecting, ensure that the power connection cable
has been disconnected from the power supply.
•
Ensure that the power connection cable is undamaged.
The unit can be connected to a power optimisation system.
Requirement
Unit not live
Power connection cable not live
Housing opened
1. Pull the power connection cable into the unit through the cable
gland.
2. Bring the power connection cable to the connection terminals.
3. Connect the power connection cable in accordance with the wiring
diagram.
4. Secure the power connection cable with cable ties.
5. Register the power optimisation system in the basic control
settings (see "Making the basic control settings").
6. Fill out the Commissioning report.