Connecting the unit
27
Installation instructions
Attaching side wall
ATTENTION
Risk of physical damage from leaky housing
•
Check seals when attaching the housing parts.
•
Replace damaged gaskets.
1. Insert the top edge of the side wall.
2. Carefully push the bottom of the side wall inwards.
3. Fasten the side wall with the screws.
4. Check that the side wall is in contact with the unit on all sides.
6.2 Making the power connection
The unit must be connected on the basis of the information on the
nameplate and this manual.
ATTENTION
Risk of physical damage from incorrect connection voltage
•
Before making the connection, measure the connection
voltage and check the set voltage on the transformers in the
unit.
Wiring diagram
The wiring diagram is included with the unit.
The wiring diagram and additional documents are available on the
manufacturer's Internet page by entering the serial number of the unit
(see Impressum).
Installation work
Electrical installation work must be carried out by an electrician.
Comply with the local regulations of the electrical utility company.
Power connection cable
Minimum requirements for the unit's power connection cable to the
electric mains:
Connection
Power connection cable
Permanent connection for fixed
installation with a cable from the unit to
a separate connection box.
Rubber sheath cable, oil-resistant,
shrouded and flexible in accordance
with IEC 60245-57 (for example
H05RN-F).
Connection of the unit with a plug.
Permanent connection for fixed
installation with a permanently laid
cable and direct connection to the unit.
PVC sheathed cable for permanent
ducting in buildings or damp and wet
rooms.