APPENDIX C: TIMING DIAGRAMS
LMV700 Nd:YVO
4
LASER MARKER
C-4
990-545
Emergency Stop condition
*7
Whenever an Emergency Stop condition is reset and the ‘Laser start input’ is turned
ON,
the ‘LD
illuminated output’ and ‘Marking standby output’ will turn
ON
.
Turning Power ON and OFF
*8
When the ‘Standby output’ and the ‘Laser start input’ are toggled
ON
during start-up, the LD will
automatically turn-on (illuminate) on startup and will turn
OFF
when shut-down.
*9
When the laser start input is turned
OFF
during normal operation, the ‘Standby output’ will toggle
OFF
during the LD cooling cycle. The ‘Standby output’ will toggle back
ON
once the LD is cool, indicating
that it is safe to turn
OFF
the main power switch.