APPENDIX C: TIMING DIAGRAMS
LMV700 Nd:YVO
4
LASER MARKER
C-2
990-545
When Laser Trouble Occurs
*4
If an internal laser error occurs, the ‘Laser error output’ will turn
ON
and the ‘Trouble’ indicator on the
front of the Control unit will turn
ON
. When laser trouble occurs the ‘Standby output’, ‘LD illuminated
output’ and ‘Marking-in-progress outputs’ will turn
OFF
.
*5
When the operator clears the error and toggles the ‘Error reset input’, the ‘LD illuminated output’ and
‘Marking standby output’ will turn back
ON
.