40
-
'10 • SCM-SM-094
'09•SRK-DB-087D
(18) Serial signal transmission error protection
(a) Purpose:
(b) Detail of operation:
(19) Rotor lock
(20) Outdoor fan motor protection
(21) Outdoor fan control at low outdoor temperature
Cooling
(a) Operating conditions:
(b) Detail of operation:
(c) Reset conditions:
Heating
(a) Operating conditions:
(b) Detail of operation:
(c) Reset conditions:
Outdoor air temperature > 10˚C
Outdoor air temperature <= 10˚C
Outdoor fan
Outdoor air temperature > 16˚C
Outdoor air temperature <= 16˚C
Lower limit speed
Cooling
(a) Start condition:
When the outdoor air temperature (Th2) has risen higher than 41°C for 30 seconds continuously while the
compressor is operating.
(b) Contents of control:
The outdoor unit fan tap is brought up by 3 steps (Higher limit is 6th tap.)
(c) Release condition:
When the compressor is turned off or the outdoor heat exchanger temperature (Th1) has dropped lower
than 40°C.
Heating
(a) Start condition:
When the outdoor air temperature (Th2) has risen higher than 13°C for 30 seconds continuously while the
compressor is operating.
(b) Contents of control:
The outdoor unit fan tap is brought down by 3 steps (Lower limit is 2nd tap.)
(c) Release condition:
When the compressor is turned off or the outdoor heat exchanger temperature (Th1) has dropped lower
than 10°C.
(22) Outdoor unit fan control at overload
40
41
ON
Under control
OFF
Normal operation
10
13
ON
Under control
OFF
Normal operation
Outdoor air temperature( )
C
Outdoor heat exchanger temperature( )
C
º
º
40
41
ON
Under control
OFF
Normal operation
10
13
ON
Under control
OFF
Normal operation
Outdoor air temperature( )
C
Outdoor heat exchanger temperature( )
C
º
º
Summary of Contents for SRR60ZJ-S
Page 52: ...51 10 SCM SM 094 09 SRK DB 087D Service data record form 45...
Page 132: ...131 10 SCM SM 094 page139 and 160 25A 2 Models SCM50ZJ S 60ZJ S...
Page 133: ...132 10 SCM SM 094...
Page 134: ...133 10 SCM SM 094...
Page 135: ...134 10 SCM SM 094...
Page 152: ...151 10 SCM SM 094 127 and 138 3 Ceiling concealed type SRR...
Page 153: ...152 10 SCM SM 094...
Page 154: ...153 10 SCM SM 094...
Page 155: ...154 10 SCM SM 094...
Page 156: ...155 10 SCM SM 094 4 Ceiling cassette 4way compact type FDTC...
Page 160: ...159 10 SCM SM 094 PJA012D783...