1-22
Item
Model
SRK35GZ-L1
SRC35GZ-L1
Cooling capacity
(1)
W
3650 [900~3900]
Heating capacity
(1)
W
4800 [900~6100]
Power source
1 Phase, 220/240V, 50Hz
Cooling input
kW
1.24 [0.35~1.60]
Running current (Cooling)
A
6.3
Heating input
kW
1.52 [0.35~2.10]
Running current (Heating)
A
7.7
Inrush current
A
7.7
COP (Cooling)
2.94
Noise level
dB (A)
Cooling: 39
Heating: 42
Cooling: 46
Heating: 47
Exterior dimensions
Height
×
Width
×
Depth
mm
275
×
790
×
174
542
×
795
×
255
Color
Ivory white
Polar white
Net weight
kg
8
35
Refrigerant equipment
Compressor type & Q’ty
–
RM5485GAE3 [Rotary type]
×
1
Motor
kW
–
0.75
Starting method
–
Line starting
Heat exchanger
Louver fins & bare tubing
Refrigerant control
Capillary tubes
Refrigerant
(4)
kg
R22
1.1 (Pre-Charged up to the piping length of 5m)
Refrigerant oil
R
0.35 (BARREL FREEZE 32SAM)
Deice control
MC control
Air handling equipment
Fan type & Q’ty
Tangential fan
×
1
Propeller fan
×
1
Motor
W
16
18
(Cooling)
7
24
Air flow (at High)
(Heating)
CMM
10
24
Air filter, Q’ty
Polypropylene net (washable)
×
2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Operation switch
Wireless-Remote controller
–
Room temperature control
MC. Thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow)
Safety equipment
O.D
mm (in)
Liquid line:
φ
6.35 (1/4
″
)
Gas line:
φ
12.7 (1/2
″
)
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.4 m
Gas line : 0.35 m
–
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source cord
2.5 m (3 cores with Earth)
Size
×
Core number
1.5 mm
2
×
4 cores (Including earth cable)
Connection wiring
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit
Optional parts
–
Notes (1) The data are measured at the following conditions.
Model SRK35GZ-L1 (Indoor unit)
SRC35GZ-L1 (Outdoor unit)
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27ºC
19ºC
35ºC
24ºC
JIS C9612, ISO-T1
Heating
20ºC
–
7ºC
6ºC
JIS C9612, ISO-T1
(2) The values for performance and power consumption shown in brackets [~] indicate the range from minimum to maximum.
(3) The operation data are applied to the 220/240V districts respectively.
(4) Limitation of Voltage application
Minimum: 198V
Maximum: 264V
(5) The refrigerant quantity to be charged includes the refrigerant in 5 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer,
(When it is 5 to 15 m, add 20 g refrigerant per meter.)
Operation data
(1)
Refrigerant
piping
Compressor: Overheat protection, heating overload protection (High pressure control), overcurrent
protection, frosting protection, serial signal error protection, indoor fan motor error protection