1-21
1.2
SELECTION DATA
1.2.1
Specifications
Model SRK25GZ-L1 (Indoor unit)
SRC25GZ-L1 (Outdoor unit)
Item
Model
SRK25GZ-L1
SRC25GZ-L1
Cooling capacity
(1)
W
2500 [900~2900]
Heating capacity
(1)
W
3400 [900~4000]
Power source
1 Phase, 220/240V, 50Hz
Cooling input
kW
0.96 [0.31~1.22]
Running current (Cooling)
A
4.8
Heating input
kW
1.17 [0.28~1.35]
Running current (Heating)
A
5.8
Inrush current
A
5.8
COP (In cooling)
2.60
Noise level
dB (A)
Cooling: 38
Heating: 39
Cooling: 46
Heating: 46
Exterior dimensions
Height
×
Width
×
Depth
mm
250
×
750
×
178
540
×
645
×
245
Color
Ivory white
Polar white
Net weight
kg
7.5
28
Refrigerant equipment
Compressor type & Q’ty
–
RM5465GA1 (Rotary type)
×
1
Motor
kW
–
0.75
Starting method
–
Line starting
Heat exchanger
Louver fins & bare tubing
Refrigerant control
Capillary tubes
Refrigerant
(4)
kg
R22
0.64 (Pre-Charged up to the piping length of 5m)
Refrigerant oil
R
0.35 (BARREL FREEZE 32SAM)
Deice control
MC control
Air handling equipment
Fan type & Q’ty
Tangential fan
×
1
Propeller fan
×
1
Motor
W
18
20
(Cooling)
7.0
21
Air flow (at High)
(Heating)
CMM
7.5
21
Air filter, Q’ty
Polypropylene net (washable)
×
2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Operation switch
Wireless-Remote controller
–
Room temperature control
MC. Thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow)
Safety equipment
O.D
mm (in)
Liquid line:
φ
6.35 (1/4
″
)
Gas line:
φ
9.52 (3/8
″
)
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.4 m
Gas line : 0.35 m
–
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source cord
2.5 m (3 cores with Earth)
Size
×
Core number
1.5 mm
2
×
4 cores (Including earth cable)
Connection wiring
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit
Optional parts
–
Notes (1) The data are measured at the following conditions.
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27ºC
19ºC
35ºC
24ºC
JIS C9612, ISO-T1
Heating
20ºC
–
7ºC
6ºC
JIS C9612, ISO-T1
(2) The values for performance and power consumption shown in brackes [~] indicate the range from minimum to maximum.
(3) The operation data are applied to the 220/240V districts respectively.
(4) Limitation of Voltage application
Minimum: 198V
Maximum: 264V
(5) The refrigerant quantity to be charged includes the refrigerant in 5 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer,
(When it is 5 to 15 m, add 20 g refrigerant per meter.)
Operation data
(1)
Refrigerant
piping
Compressor: Overheat protection, heating overload protection (High pressure control), overcurrent pro-
tection, serial signal error protection, indoor fan motor error protection
Summary of Contents for SRC208CENF-L
Page 26: ...Models SRK50A 56A...
Page 40: ...1 40 Model SRK502Z L...