1-3
1.1 GENERAL INFORMATION
1.1.1 Specific features
The “Mitsubishi Daiya” room air conditioner:
SRK series
are of split and wall mounted type and the unit consists of indoor unit
and outdoor unit with refrigerant precharged in factory. The indoor unit is composed of room air cooling or heating equipment with
operation control switch and the outdoor unit is composed of condensing unit with compressor.
(1)
Remote control flap
The flap can be automatically controlled by operating wireless remote control.
¡
AUTO (Natural flow) :
Flap operation is automatically control.
¡
Swing
:
This will swing the flap up and down.
¡
Memory flap :
Once the flap position is set, the unit memorizes the position and continues to
operate at the same position from the next time.
(2)
Automatic Operation
When the remote control switch is set on “auto”, it will either automatically decide operation mode such as cooling,
heating and thermal dry, or operate in the operation mode before it has been turned to automatic control.
(3)
Self diagnosis Function
We are constantly trying to do better service to our customers by installing such judges that show abnormality of operation
as follows.
1.1.2 How to read the model name
Example :
SR
K
32
8
H
EN
F
-
L
CE marking model
Flare connecting
Applicable power source …… See the specifications
H-Heat pump type C-Cool only type
Series No.
Product capacity
Wall mounted type room air conditioner
Split type room air conditioner
Abnormality of room
temperature sensor.
TIMER lamp is
light up.
RUN lamp is flashing.
(1 Times/ 8sec.)
RUN lamp is flashing.
(2 Times/ 8sec.)
Abnormality of heat
exchanger sensor.
Abnormality of indoor
fan motor.
RUN lamp is flashing.
(6 Times/ 8sec.)
t
t
t
Abnormality of outdoor
unit.
RUN lamp is light
up.
TIMER lamp is flashing.
(5 Times/ 8sec.)
t
t
No lamps will flashing
when the unit is operating.
}