1-13
(2) The operation data are applied to the 220 V or 240 V districts respectively.
(3) Limitation of Voltage application
Minimum: 198 V
Maximum: 264 V
(4) The refrigerant quantity to be charged includes the refrigerant in 7.5 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, (when it is less than 10 m, add 10 g refrigerant per meter and when it is 10 to 15 m, add 30 g refrigerant per meter.)
(5) Expressed in sound pressure level.
Notes
(1) The data are measured at the following conditions.
Model SRK258CENF-L (Indoor unit)
SRC258CENF-L (Outdoor unit)
Item
Model
SRK258CENF-L
SRC258CENF-L
Cooling capacity
(1)
W
2200/2250
Power source
1 Phase. 220/240 V, 50 Hz
Cooling input
kW
0.66/0.74
Running current (Cooling)
A
3.3/3.4
Inrush current
A
17.3/18.9
COP (In cooling)
3.33/3.04
Noise level
(5)
dB (A)
38/39
41/42
Exterior dimensions
mm
275
×
790
×
174
542
×
795
×
255
Height
×
Width
×
Depth
Color
Ivory white
Polar white
Net weight
kg
7.5
31
Refrigerant equipment
–
RM5485GNE1 (Rotary type)
×
1
Compressor types & Q’ty
Motor
kW
–
0.6
Starting method
–
Line starting
Heat exchanger
Louver fins & inner grooved tubing
Refrigerant control
Capillary tubes
Refrigerant
(4)
kg
R22 0.71
Refrigerant oil
R
0.3 (BARREL FREEZE 32SAM)
Air handling equipment
Tangential fan
×
1
Propeller fan
×
1
Fan type & Q’ty
Motor
W
16
11
Air flow (at High)
CMM
7.5/7.5
22/22
Air filter, Q’ty
Polypropylene net (washable)
×
2
–
Shock & vibration absorber
–
Cushion rubber (for compressor)
Electric heater
–
–
Operation control
Wireless-Remote controller
–
Operation switch
Room temperature control
MC. Thermostat
–
Pilot lamp
RUN (Green), TIMER (Yellow)
–
Safety equipment
–
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
O.D
mm (in)
Liquid line:
φ
6.35 (1/4") Gas line:
φ
9.52 (3/8")
Connecting method
Flare connecting
Attached length of piping
Liquid line: 0.4 m
–
Gas line : 0.35 m
Insulation
Necessary (Both sides)
Drain hose
Connectable
Power source cord
2.5 m (3 cores with Earth)
Size
×
Core number
1.5 mm
2
×
3 cores (Including earth cable)
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit
Optional parts
–
Connection
wiring
Operation
data
(1)
Refrigerant
piping
Item
Indoor air temperature
Outdoor air temperature
Standards
Operation
DB
WB
DB
WB
Cooling
27
°
C
19
°
C
35
°
C
24
°
C
JIS C9612, ISO-T1
Summary of Contents for SRC208CENF-L
Page 26: ...Models SRK50A 56A...