![Mitsubishi MR-JE-100B Instruction Manual Download Page 259](http://html1.mh-extra.com/html/mitsubishi/mr-je-100b/mr-je-100b_instruction-manual_1808431259.webp)
11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 46
(b) For 1-phase 200 V AC to 240 V AC power supply of MR-JE-10B to MR-JE-100B
MCCB
Servo amplifier
1
2
3
(Note 2)
Surge protector
(RSPD-250-U4)
(OKAYA Electric Industries Co., Ltd.)
(Note 1)
1-phase
200 V AC to 240 V AC
1
2
3
MC
EMC filter
L1
L2
L3
4
5
6
E
Note 1. Connect the power supply to L1 and L3. Leave L2 open.
2. The example is when a surge protector is connected.
(c) For 1-phase 200 V AC to 240 V AC power supply of MR-JE-200B
MCCB
Servo amplifier
1
2
3
(Note 2)
Surge protector
(RSPD-250-U4)
(OKAYA Electric Industries Co., Ltd.)
(Note 1)
1-phase
200 V AC to 240 V AC
1
2
3
MC
EMC filter
L1
L2
L3
4
5
6
E
Note 1. Connect the power supply to L1 and L2. Leave L3 open.
2. The example is when a surge protector is connected.