11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 26
11.5.3 MR-BT6VCASE battery case
POINT
The battery unit consists of an MR-BT6VCASE battery case and five MR-
BAT6V1 batteries.
For the specifications and the year and month of manufacture of the MR-
BAT6V1 battery, refer to section 11.5.4.
MR-BT6VCASE is a case used for connecting and mounting five MR-BAT6V1 batteries. No battery is
included in the battery case. Prepare MR-BAT6V1 batteries separately.
(1) Number of connectable servo motors
One MR-BT6VCASE case can hold the absolute position data of up to 8-axis servo motors. Servo
motors in an incremental system are included as the axis numbers.
(2) Dimensions
[Unit: mm]
Mounting hole process drawing
2-M4 screw
Approx. 25
Approx. 130
Approx. 5
Approx. 5
120 ± 0.5
5
5
5
130
Approx. 70
25
130
4.6
120
5
2- 5 mounting
hole
Mounting screw
Screw size: M4
[Mass: 0.18 kg]