8. TROUBLESHOOTING
8 - 5
No. Name
Detail
No.
Detail name
Stop
method
(Note 2,
3)
Alarm deactivation
Alarm
reset
CPU
reset
Power
cycling
Alarm
8A
USB communication
time-out error/serial
communication time-
out error/Modbus RTU
communication time-
out error
8A.1
USB communication time-out
error/serial communication time-
out error
SD
8A.2
Modbus RTU communication time-
out error
SD
8C.1
Network module communication
error 1
SD
8C.2
Network module communication
error 2
SD
Network module
communication error
8C.3
Network module communication
error 3
SD
8C 8C.4
Network module communication
error 4
SD
8C.5
Network module communication
error 5
SD
8C.6
Network module communication
error 6
SD
8C.7
Network module communication
error 7
SD
8E
USB communication
error/serial
communication
error/Modbus RTU
communication error
8E.1
USB communication receive
error/serial communication receive
error
SD
8E.2
USB communication checksum
error/serial communication
checksum error
SD
8E.3
USB communication character
error/serial communication
character error
SD
8E.4
USB communication command
error/serial communication
command error
SD
8E.5
USB communication data number
error/serial communication data
number error
SD
8E.6
Modbus RTU communication
receive error
SD
8E.7
Modbus RTU communication
message frame error
SD
8E.8
Modbus RTU communication CRC
error
SD
888/
88888
Watchdog
88._/
8888._
Watchdog DB
Note 1. After resolving the source of trouble, cool the equipment for approximately 30 minutes.
2. The following shows three stop methods of DB, EDB, and SD.
DB: Dynamic brake stop (For a servo amplifier without the dynamic brake, the servo motor coasts.)
EDB: Electronic dynamic brake stop (available with specified servo motors)
Refer to the following table for the specified servo motors. The stop method for other than the specified
servo motors is DB.
For MR-JE_A, setting [Pr. PF09] to "(_ _ _ 3)" enables the electronic dynamic brake.
Series Servo
motor
HG-KN HG-KN053/HG-KN13/HG-KN23/HG-KN43
HG-SN HG-SN52
SD: Forced stop deceleration
3. This is applicable when [Pr. PA04] is set to the initial value. The stop method of SD can be changed to DB using
[Pr. PA04].
4. In some controller communication status, the alarm factor may not be removed.