![Mitsubishi MR-JE-100B Instruction Manual Download Page 112](http://html1.mh-extra.com/html/mitsubishi/mr-je-100b/mr-je-100b_instruction-manual_1808431112.webp)
5. PARAMETERS
5 - 17
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
PA25 OTHOV One-touch tuning - Overshoot permissible level
Set a permissible value of the overshoot amount for one-touch tuning as a percentage of the
in-position range.
However, setting "0" will be 50%.
0
[%]
0 to 100
PA26
*AOP5 Function selection A-5
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x
Torque limit function selection at instantaneous power failure
(instantaneous power failure tough drive selection)
0: Disabled
1: Enabled
When an instantaneous power failure occurs during operation, you
can save electric energy charged in the capacitor in the servo
amplifier by limiting torque at acceleration. You can also delay the
time until the occurrence of [AL. 10.2 Bus voltage drop] with the
instantaneous power failure tough drive function. Doing this will
enable you to set a longer time in [Pr. PF25 Instantaneous power
failure tough drive - Detection time].
The torque limit function at instantaneous power failure is enabled
when "instantaneous power failure tough drive selection" in [Pr.
PA20] is "Enabled (_ 1 _ _)".
0h
_ _ x _
For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PA27
*HTL
Hot line forced stop function
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x
Hot line forced stop function selection
0: Enabled
1: Disabled
0h
_ _ x _
For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PA28 **AOP6 Function selection A-6
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x
Selection of the HG-KN series servo motor maximum speed
Select the maximum speed of the HG-KN series servo motor.
0: A maximum speed of 5000 r/min
1: A maximum speed of 6000 r/min
This digit is disabled when a servo motor other than HG-KN series
is connected.
This digit is available with servo amplifier with software version C4
or later.
0h
_ _ x _
For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
Summary of Contents for MR-JE-100B
Page 9: ...A 8 MEMO...
Page 15: ...6 MEMO...
Page 79: ...3 SIGNALS AND WIRING 3 44 MEMO...
Page 95: ...4 STARTUP 4 16 MEMO...
Page 193: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 30 MEMO...