11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 8
11.2 Regenerative option
CAUTION
Do not use servo amplifiers with regenerative options other than the combinations
specified below.
Otherwise, it may cause a fire.
11.2.1 Combination and regenerative power
The power values in the table are resistor-generated powers and not rated powers.
Servo
amplifier
Regenerative power [W]
Built-in
regenerative
resistor
MR-RB032
[40
Ω
]
MR-RB12
[40
Ω
]
MR-RB30
[13
Ω
]
MR-RB32
[40
Ω
]
(Note)
MR-RB50
[13
Ω
]
MR-JE-10B
30
MR-JE-20B 30 100
MR-JE-40B 10 30 100
MR-JE-70B
20 30 100 300
MR-JE-100B
20 30 100 300
MR-JE-200B
100 300 500
MR-JE-300B
100 300 500
Note. Always install a cooling fan.