14
• Instructions can be executed under the following conditions.
• The following devices can be used.
*1
For details on each device, refer to the following
MELSEC-L CPU Module User's Manual (Function Explanation, Program Fundamentals)
*2
FX and FY can be used for bit data only, and FD for word data only.
*3
In the "Constant" and "Others" columns, a device(s) that can be set for each instruction is shown.
• The following data types can be used.
Execution condition
Any time
During on
On the falling
edge
During off
On the falling
edge
Symbol
No symbol
Setting
data
Internal device
(system, user)
File
register
Link direct device
J
\
Intelligent
function
module
U
\G
Index
register
Zn
Con
stant
*3
Other
*3
Bit
Word
Bit
Word
Applicable
device
*1
X,Y,M,L,S
M,F,B,SB,F
X,FY
*2
T,ST,C,D,W,
SD,SW,FD,
@
R,ZR
-
U
\G
Z
K, H,
E, $
P,I,J,U,D
X,DY,N,B
L,TR,BL\
S,V
Data type
Description
Bit
Bit data or the start number of bit data
BIN 16-bit
16-bit binary data or the start number of word device
BIN 32-bit
32-bit binary data or the start number of double-word device
BCD 4-digit
Four-digit binary-coded decimal data
BCD 8-digit
Eight-digit binary-coded decimal data
Real number
Floating-point data
Character string
Character string data
Device name
Device name data