50
(b) Devices used in the program
The following table lists the device numbers and applications used in the sample program.
Device number
Application
M3000
Send direction
D3000 and D3001
SP.SOCSND instruction control data
M300 and M301
SP.SOCSND instruction completion device
D300 and D303
Send data length and send data (6 bytes of 12
H
, 34
H
, 56
H
, 78
H
, 9A
H
, and BC
H
)
M3002
Normal send indication
M3003
Send error indication
D5000 to D5001
SP.SOCRCV instruction control data
M500 to M501
SP.SOCRCV instruction completion device
SD1282
Open completion signal
SD1286
Receive state signal
SD1288
Connection state signal
M3001
Target change direction
D500 and higher
Receive data length and receive data
M5002
Normal receive indication
M5003
Receive error indication
D400 to D404
SP.SOCCSET instruction control data
D450 to D451
SP.SOCCINF instruction control data
D460 to D464
SP.SOCCINF instruction connection information