M800S/M80 Series Connection and Setup Manual
17 Setting the Hardware
338
IB-1501269-F
17.6.4.1 Fixed Device Assignment
(1) By setting the parameter "#53001 RIO dev assign" to "0", the PLC device assignment method, which is to be used
for input/output of each remote I/O unit station, will be the fixed device assignment.
(2) PLC devices assigned for each remote I/O unit station at the time of the fixed device assignment are as follows:
(Note)
Do not use the input/output signals of the system-occupied stations of RIO3 and operation panel I/O unit-
connected channels.
(3) A part of PLC devices assigned for each station of remote I/O units can input/output signals with PLC high speed by
setting the high-speed input/output specification parameters or R registers.
(a) The devices for inputting/outputting signals with PLC high speed can be set individually for the high-order and
the low-order per 16 points for DI and DO of each remote I/O unit station.
(b) Only devices of the first to eighth stations for each remote I/O channel can input/output signals with PLC high
speed. The devices of the ninth to 64th stations input/output with PLC medium speed.
(c) The parameter and R register numbers for the high-speed input/output designation are as follows:
(Note 1) The above parameters are invalid when the devices have been assigned arbitrarily.
(Note 2) Refer to "PLC Programming Manual" for the details of the setting method.
Station No.
Channel No.
1
2
…
8
9
…
63
64
RIO1
Input device
X0000
to X001F
X0020
to X003F
…
X00E0
to X00FF
ZR5000
/ ZR5001
…
ZR5108
/ ZR5109
ZR5110
/ ZR5111
Output device
Y0000
to Y001F
Y0020
to Y003F
…
Y00E0
to Y00FF
ZR6000
/ ZR6001
…
ZR6108
/ ZR6109
ZR6110
/ ZR6111
RIO2
Input device
X0100
to X011F
X0120
to X013F
…
X01E0
to X01FF
ZR5200
/ ZR5201
…
ZR5308
/ ZR5309
ZR5310
/ ZR5311
Output device
Y0100
to Y011F
Y0120
to Y013F
…
Y01E0
to Y01FF
ZR6200
/ ZR6201
…
ZR6308
/ZR6309
ZR6310
/ ZR6311
RIO3
Input device
X0200
to X021F
X0220
to X023F
…
X02E0
to X02FF
ZR5400
/ ZR5401
…
ZR5508
/ ZR5509
ZR5510
/ ZR5511
Output device
Y0200
to Y021F
Y0220
to Y023F
…
Y02E0
to Y02FF
ZR6400
/ ZR6401
…
ZR6508
/ ZR6509
ZR6510
/ ZR6511
Station No.
Channel No.
1 to 4
5 to 8
Parameter No.
R register No.
Parameter No.
R register No.
RIO1
High-speed input
specification
#
6457
R7828 low-order
#
6458
R7828 high-order
High-speed output
specification
#
6461
R7830 low-order
#
6462
R7830 high-order
RIO2
High-speed input
specification
#
6459
R7829 low-order
#
6460
R7829 high-order
High-speed output
specification
#
6463
R7831 low-order
#
6464
R7831 high-order
RIO3
High-speed input
specification
#
6465
R7832 low-order
#
6466
R7832 high-order
High-speed output
specification
#
6473
R7836 low-order
#
6474
R7836 high-order
Summary of Contents for M80 series
Page 1: ......
Page 4: ......
Page 9: ......
Page 21: ......
Page 23: ......
Page 25: ......
Page 27: ......
Page 29: ......
Page 37: ......
Page 38: ...1 IB 1501269 F 1 System Basic Configuration...
Page 40: ...3 IB 1501269 F 2 General Connection Diagram...
Page 44: ...7 IB 1501269 F 3 List of Configuration...
Page 53: ...M800S M80 Series Connection and Setup Manual 3 List of Configuration 16 IB 1501269 F...
Page 54: ...17 IB 1501269 F 4 General Specifications...
Page 185: ...M800S M80 Series Connection and Setup Manual 4 General Specifications 148 IB 1501269 F...
Page 186: ...149 IB 1501269 F 5 Installation...
Page 211: ...M800S M80 Series Connection and Setup Manual 5 Installation 174 IB 1501269 F...
Page 212: ...175 IB 1501269 F 6 Precautions for Connecting...
Page 219: ...M800S M80 Series Connection and Setup Manual 6 Precautions for Connecting 182 IB 1501269 F...
Page 220: ...183 IB 1501269 F 7 Connection of Control Unit...
Page 245: ...M800S M80 Series Connection and Setup Manual 7 Connection of Control Unit 208 IB 1501269 F...
Page 246: ...209 IB 1501269 F 8 Connection of Keyboard Unit...
Page 248: ...211 IB 1501269 F 9 Connection of Operation Panel I O Unit...
Page 262: ...225 IB 1501269 F 10 Connection of Remote I O Unit...
Page 289: ...M800S M80 Series Connection and Setup Manual 10 Connection of Remote I O Unit 252 IB 1501269 F...
Page 290: ...253 IB 1501269 F 11 Connection of Manual Pulse Generator...
Page 294: ...257 IB 1501269 F 12 Connection of Synchronous Feed Encoder...
Page 296: ...259 IB 1501269 F 13 Connection of MITSUBISHI CNC Machine Operation Panel...
Page 308: ...271 IB 1501269 F 14 Connection of Handy Terminal...
Page 310: ...273 IB 1501269 F 15 Cable...
Page 349: ...M800S M80 Series Connection and Setup Manual 15 Cable 312 IB 1501269 F...
Page 350: ...313 IB 1501269 F 16 Setup Outline...
Page 354: ...317 IB 1501269 F 17 Setting the Hardware...
Page 383: ...M800S M80 Series Connection and Setup Manual 17 Setting the Hardware 346 IB 1501269 F...
Page 384: ...347 IB 1501269 F 18 Setting Up with M80 M800S SETUP INSTALLER...
Page 392: ...355 IB 1501269 F 19 Setting the Parameters and Date Time...
Page 398: ...361 IB 1501269 F 20 PLC Program Writing...
Page 410: ...373 IB 1501269 F 21 Confirming the Basic Operation...
Page 416: ...379 IB 1501269 F 22 Setting the Position Detection System...
Page 440: ...403 IB 1501269 F 23 Setting the Tool Entry Prohibited Range...
Page 454: ...417 IB 1501269 F 24 Confirming the Spindle Operation...
Page 458: ...421 IB 1501269 F 25 Setting the Handy Terminal...
Page 464: ...427 IB 1501269 F 26 Setting the Deceleration Check...
Page 474: ...437 IB 1501269 F 27 Adjust S analog Screen...
Page 479: ...M800S M80 Series Connection and Setup Manual 27 Adjust S analog Screen 442 IB 1501269 F...
Page 480: ...443 IB 1501269 F 28 Device Open Parameter Screen...
Page 486: ...449 IB 1501269 F 29 SRAM Open Parameter Screen...
Page 492: ...455 IB 1501269 F 30 Data Backup and Restoration...
Page 498: ...461 IB 1501269 F 31 Appx 1 Setting the System Lock...
Page 502: ...465 IB 1501269 F 32 Appx 2 Protection Setting...
Page 510: ...473 IB 1501269 F 33 Appx 3 Displaying Original Logo On Standard Screen...
Page 512: ...475 IB 1501269 F 34 Appx 4 EMC Installation Guidelines...
Page 524: ...487 IB 1501269 F 35 Appx 5 Restrictions for Lithium Batteries...
Page 532: ...495 IB 1501269 F 36 Appx 6 Precautions for Compliance to UL c UL Standards...
Page 538: ......
Page 542: ......