22 Setting the Position Detection System
395
IB-1501269-F
22.1.8 Precautions Common for the Dogless-type Absolute Position Detector
(1) Example of setting "#2 Zero-P" parameter
For the "#2 Zero-P" parameter, set the coordinate value of the absolute position origin point (mechanical basic
position or electrical basic position" looking from the basic machine coordinate system zero point.
(2) Setting the reference position
The reference position can be set as shown below by setting the "#2037 G53ofs".
(3) When an MPI scale made by Mitsubishi Heavy Industries Machine Tool Co., Ltd. is used, set the zero point return
parameters so that Z phase of the MPI scale becomes the grid point (electric basic position), and then perform zero
point initialization setting.
(Example 1) To set the zero point
at 50.0mm before absolute
position origin point on + end
(Example 2) To set the zero point
at 400.0mm before the machine
basic position or absolute position
origin point on - end.
(Example 3) To set the basic machine coordinate system zero point on the grid point, calculate the "#2 Zero-P" parameter
setting value as shown below using the value displayed at "Machine end". "Machine end" shows the distance from the
mechanical basic position to the previous grid point.
(Note that when setting the electrical basic position coordinate value in "#2 Zero-P", the "Machine end" value does not
need to be considered.)
To set the third gird point as the
zero point when the "Machine
end"display is -5.3 at the + end
basic position. (Example of
10.0mm grid interval.)
(Example 1) To set the reference
position to the same position as
the basic machine coordinate
system zero point.
(Example 2) To set the reference
position at a position 200.0mm to
the + side from the basic machine
coordinate zero point.
(To set the basic machine
coordinate system zero point
300.0mm front of the absolute
position origin point.)
Basic machine coordinate
system zero point
"#2 Zero-P" = 50.0
Absolute position
origin point
(Mechanical basic
position or electrical
basic position)
"#2 Zero-P" = 400.0
Absolute position
origin point
Basic machine
coordinate system
zero point
(Mechanical basic
position or electrical
basic position)
10.0
10.0
"Machine end" = -5.3
"#2 Zero-P" = 25.3
Basic machine coordinate
system zero point
Mechanical
basic position
Basic machine
coordinate system
zero point
Reference
position
"G53ofs" = 0
"#2 Zero-P"
Absolute position
origin point
(Mechanical basic
position or electrical
basic position)
"G53ofs" = 200.0
Reference position
"#2 Zero-P" = 300.0
Absolute
position
origin point
Basic machine
coordinate
system
zero point
(Mechanical
basic position
or electric
basic position)
Summary of Contents for M80 series
Page 1: ......
Page 4: ......
Page 9: ......
Page 21: ......
Page 23: ......
Page 25: ......
Page 27: ......
Page 29: ......
Page 37: ......
Page 38: ...1 IB 1501269 F 1 System Basic Configuration...
Page 40: ...3 IB 1501269 F 2 General Connection Diagram...
Page 44: ...7 IB 1501269 F 3 List of Configuration...
Page 53: ...M800S M80 Series Connection and Setup Manual 3 List of Configuration 16 IB 1501269 F...
Page 54: ...17 IB 1501269 F 4 General Specifications...
Page 185: ...M800S M80 Series Connection and Setup Manual 4 General Specifications 148 IB 1501269 F...
Page 186: ...149 IB 1501269 F 5 Installation...
Page 211: ...M800S M80 Series Connection and Setup Manual 5 Installation 174 IB 1501269 F...
Page 212: ...175 IB 1501269 F 6 Precautions for Connecting...
Page 219: ...M800S M80 Series Connection and Setup Manual 6 Precautions for Connecting 182 IB 1501269 F...
Page 220: ...183 IB 1501269 F 7 Connection of Control Unit...
Page 245: ...M800S M80 Series Connection and Setup Manual 7 Connection of Control Unit 208 IB 1501269 F...
Page 246: ...209 IB 1501269 F 8 Connection of Keyboard Unit...
Page 248: ...211 IB 1501269 F 9 Connection of Operation Panel I O Unit...
Page 262: ...225 IB 1501269 F 10 Connection of Remote I O Unit...
Page 289: ...M800S M80 Series Connection and Setup Manual 10 Connection of Remote I O Unit 252 IB 1501269 F...
Page 290: ...253 IB 1501269 F 11 Connection of Manual Pulse Generator...
Page 294: ...257 IB 1501269 F 12 Connection of Synchronous Feed Encoder...
Page 296: ...259 IB 1501269 F 13 Connection of MITSUBISHI CNC Machine Operation Panel...
Page 308: ...271 IB 1501269 F 14 Connection of Handy Terminal...
Page 310: ...273 IB 1501269 F 15 Cable...
Page 349: ...M800S M80 Series Connection and Setup Manual 15 Cable 312 IB 1501269 F...
Page 350: ...313 IB 1501269 F 16 Setup Outline...
Page 354: ...317 IB 1501269 F 17 Setting the Hardware...
Page 383: ...M800S M80 Series Connection and Setup Manual 17 Setting the Hardware 346 IB 1501269 F...
Page 384: ...347 IB 1501269 F 18 Setting Up with M80 M800S SETUP INSTALLER...
Page 392: ...355 IB 1501269 F 19 Setting the Parameters and Date Time...
Page 398: ...361 IB 1501269 F 20 PLC Program Writing...
Page 410: ...373 IB 1501269 F 21 Confirming the Basic Operation...
Page 416: ...379 IB 1501269 F 22 Setting the Position Detection System...
Page 440: ...403 IB 1501269 F 23 Setting the Tool Entry Prohibited Range...
Page 454: ...417 IB 1501269 F 24 Confirming the Spindle Operation...
Page 458: ...421 IB 1501269 F 25 Setting the Handy Terminal...
Page 464: ...427 IB 1501269 F 26 Setting the Deceleration Check...
Page 474: ...437 IB 1501269 F 27 Adjust S analog Screen...
Page 479: ...M800S M80 Series Connection and Setup Manual 27 Adjust S analog Screen 442 IB 1501269 F...
Page 480: ...443 IB 1501269 F 28 Device Open Parameter Screen...
Page 486: ...449 IB 1501269 F 29 SRAM Open Parameter Screen...
Page 492: ...455 IB 1501269 F 30 Data Backup and Restoration...
Page 498: ...461 IB 1501269 F 31 Appx 1 Setting the System Lock...
Page 502: ...465 IB 1501269 F 32 Appx 2 Protection Setting...
Page 510: ...473 IB 1501269 F 33 Appx 3 Displaying Original Logo On Standard Screen...
Page 512: ...475 IB 1501269 F 34 Appx 4 EMC Installation Guidelines...
Page 524: ...487 IB 1501269 F 35 Appx 5 Restrictions for Lithium Batteries...
Page 532: ...495 IB 1501269 F 36 Appx 6 Precautions for Compliance to UL c UL Standards...
Page 538: ......
Page 542: ......