M800S/M80 Series Connection and Setup Manual
6 Precautions for Connecting
179
IB-1501269-F
6.1.2 Precautions for Using Optical Communication Cable
An optical communication cable is used for communication between the control unit and the drive unit.
Special precautions, differing from the conventional cable, are required when laying and handling the optical
communication cable.
(Note)
If the cable you use is not Mitsubishi's, malfunctions resulted from connection problems or aged deterioration
are not covered under the warranty.
To ensure the system performance and reliability, purchase the optical communication cable from Mitsubishi. A
machining drawing is given in "Cable" as reference, but the purchased optical communication cable cannot be cut or
connected by the machine tool builder.
(1) A protective cap is attached to the optical module and optical communication cable mounted on the PCB when the
system is delivered. Leaving this protective cap unattached could result in connection faults from the adherence of
dirt and dust. Do not remove the protective cap when not connecting the cable. If dirty, wipe off lightly with a piece
of dry gauze, etc. (Do not use solvents such as alcohol as the optical fiber material could melt.)
(2) Hold the connector section when connecting or disconnecting the optical connector. Holding the fiber cord will result
in force exceeding the tolerable tension on the fiber cord and connector connection section, and could cause the
fiber cord to dislocate from the optical connector thereby inhibiting use.
(3) The optical connector cannot be connected in reversed. Check the connector orientation when connecting the
optical communication cable to the optical module. Align the connector lock lever with the lock holes on the PCB's
optical module, and press the connector straight in. Confirm that the lock lever connects with the optical module and
that a "click" is heard.
(4) When disconnecting the optical communication cable from the PCB, press the lock release buttons on the lock
lever, and pull out the cable while holding the connector section. The connector could be damaged if the cable is
pulled without pressing down on the lock release buttons.
(5) Do not apply excessive force onto the optical communication cable by stepping on it or dropping tools, etc., on it.
Optical communication cable outline and parts
Precautions for handling optical communication cable
20.3
22.7
150
35
7
Optical connector
Fiber code/connector connection section
Fiber cord
Bushing
Reinforced
sheath
Summary of Contents for M80 series
Page 1: ......
Page 4: ......
Page 9: ......
Page 21: ......
Page 23: ......
Page 25: ......
Page 27: ......
Page 29: ......
Page 37: ......
Page 38: ...1 IB 1501269 F 1 System Basic Configuration...
Page 40: ...3 IB 1501269 F 2 General Connection Diagram...
Page 44: ...7 IB 1501269 F 3 List of Configuration...
Page 53: ...M800S M80 Series Connection and Setup Manual 3 List of Configuration 16 IB 1501269 F...
Page 54: ...17 IB 1501269 F 4 General Specifications...
Page 185: ...M800S M80 Series Connection and Setup Manual 4 General Specifications 148 IB 1501269 F...
Page 186: ...149 IB 1501269 F 5 Installation...
Page 211: ...M800S M80 Series Connection and Setup Manual 5 Installation 174 IB 1501269 F...
Page 212: ...175 IB 1501269 F 6 Precautions for Connecting...
Page 219: ...M800S M80 Series Connection and Setup Manual 6 Precautions for Connecting 182 IB 1501269 F...
Page 220: ...183 IB 1501269 F 7 Connection of Control Unit...
Page 245: ...M800S M80 Series Connection and Setup Manual 7 Connection of Control Unit 208 IB 1501269 F...
Page 246: ...209 IB 1501269 F 8 Connection of Keyboard Unit...
Page 248: ...211 IB 1501269 F 9 Connection of Operation Panel I O Unit...
Page 262: ...225 IB 1501269 F 10 Connection of Remote I O Unit...
Page 289: ...M800S M80 Series Connection and Setup Manual 10 Connection of Remote I O Unit 252 IB 1501269 F...
Page 290: ...253 IB 1501269 F 11 Connection of Manual Pulse Generator...
Page 294: ...257 IB 1501269 F 12 Connection of Synchronous Feed Encoder...
Page 296: ...259 IB 1501269 F 13 Connection of MITSUBISHI CNC Machine Operation Panel...
Page 308: ...271 IB 1501269 F 14 Connection of Handy Terminal...
Page 310: ...273 IB 1501269 F 15 Cable...
Page 349: ...M800S M80 Series Connection and Setup Manual 15 Cable 312 IB 1501269 F...
Page 350: ...313 IB 1501269 F 16 Setup Outline...
Page 354: ...317 IB 1501269 F 17 Setting the Hardware...
Page 383: ...M800S M80 Series Connection and Setup Manual 17 Setting the Hardware 346 IB 1501269 F...
Page 384: ...347 IB 1501269 F 18 Setting Up with M80 M800S SETUP INSTALLER...
Page 392: ...355 IB 1501269 F 19 Setting the Parameters and Date Time...
Page 398: ...361 IB 1501269 F 20 PLC Program Writing...
Page 410: ...373 IB 1501269 F 21 Confirming the Basic Operation...
Page 416: ...379 IB 1501269 F 22 Setting the Position Detection System...
Page 440: ...403 IB 1501269 F 23 Setting the Tool Entry Prohibited Range...
Page 454: ...417 IB 1501269 F 24 Confirming the Spindle Operation...
Page 458: ...421 IB 1501269 F 25 Setting the Handy Terminal...
Page 464: ...427 IB 1501269 F 26 Setting the Deceleration Check...
Page 474: ...437 IB 1501269 F 27 Adjust S analog Screen...
Page 479: ...M800S M80 Series Connection and Setup Manual 27 Adjust S analog Screen 442 IB 1501269 F...
Page 480: ...443 IB 1501269 F 28 Device Open Parameter Screen...
Page 486: ...449 IB 1501269 F 29 SRAM Open Parameter Screen...
Page 492: ...455 IB 1501269 F 30 Data Backup and Restoration...
Page 498: ...461 IB 1501269 F 31 Appx 1 Setting the System Lock...
Page 502: ...465 IB 1501269 F 32 Appx 2 Protection Setting...
Page 510: ...473 IB 1501269 F 33 Appx 3 Displaying Original Logo On Standard Screen...
Page 512: ...475 IB 1501269 F 34 Appx 4 EMC Installation Guidelines...
Page 524: ...487 IB 1501269 F 35 Appx 5 Restrictions for Lithium Batteries...
Page 532: ...495 IB 1501269 F 36 Appx 6 Precautions for Compliance to UL c UL Standards...
Page 538: ......
Page 542: ......